期刊文献+

大中型商业建筑被动式过滤通风技术构想及分析 被引量:1

Study on the Technical Concept and Problem of Passive Filter Ventilation of Large and Medium-size Commercial Building
下载PDF
导出
摘要 我国大中型商业建筑普遍存在能耗大、空气质量差的问题。为此,提出了被动式过滤通风系统基本构想,设想利用烟囱效应,在建筑中设置拔风系统,在墙上设置空气过滤网,为建筑提供充足的洁净新风。其后,分析了该系统的核心问题,并利用CFD软件对其进行了研究,理论证明了该系统的技术可行性。 The Large and medium-sized commercial buildings in our country have problems of large energy consumption,poor air quality.Therefore,this paper presents the basic idea about passive filtered ventilation system,conceived using the stack effect,set the wind pull system in the building and set up the air filter on the wall to provide adequate clean and fresh air for building.Then,analysis the core issues about this system,and researched by CFD software,theoretical proof the technical feasibility of this system.
出处 《建筑热能通风空调》 2014年第6期15-18,共4页 Building Energy & Environment
基金 武汉市建委科研项目(201242)
关键词 商业建筑 被动式通风 过滤式通风 CFD模拟 commercial buildings,passive ventilation,filter ventilation,CFD simulation
  • 相关文献

参考文献5

二级参考文献25

  • 1黄维,陆荫,常沁春,白亮,赵红,刘文君.兰州市新装修室内环境空气污染特征[J].环境与健康杂志,2007,24(2):101-103. 被引量:16
  • 2王远,魏庆芃,薛志峰,江亿.大型公建节能会诊(三)——调查分析篇 大型公共建筑能耗调查分析[J].建设科技,2007(2):17-19. 被引量:24
  • 3江亿,等.2007年中国建筑节能年度发展研究报告[R].北京:中国建筑工业出版社,2007.
  • 4[3]建设部.2005年城镇房屋概况统计公报[K].(Ministry of Construction of the People's Republic of China.Statistical Communique of the City and Town Building General Situation In 2005[K].)
  • 5Cardinal N, Micucci M, Ruggiero F Analysis of energy saving using natural ventilation in a traditional Italian building [J].Energy and Bdildings, 2003, 35 (2) 153159.
  • 6Preeda Chantawong, Jongiit Hirunlabh, Belkacem Zeghmati, et al. Investigation on thermal performance of glazed solar chimney walls[J]. Solar Energy, 2006,80(3) : 288- 297.
  • 7Sompop Punyasompun, Jongjit Hirunlabh, Joseph Khedari, et al. Investigation on the application of solar chimney for multi-storey buildings [J]. Renewable Energy, 2009,34(12) : 2545- 2561.
  • 8Kumari S, Sinha S, Kumar N. Experimental investigation of solar chimney assisted bioclimatic architecture [ J]. Energy Conversion and Management, 1998,39(5/6) .441-444.
  • 9Khedari J, Hirunlabh J, Bunnag T. Experimental study of a roof solar collector towards the natural ventilation of new houses[J]. Engery and Buildings, 1997,26(2) : 159-164.
  • 10Chen Z D, Bandopadhayay P, Halldorsson J, et al. An experimental investigation of a solar chimneY model with uniform wall heat flux[J]. Building and Environment, 2003,38(7) : 893- 906.

共引文献33

同被引文献6

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部