摘要 新风换气机作为一种新型的通风换气设备,通过换热芯体回收部分室内排风冷(热)量。为有效提高新风换气机的换热效率,利用直接蒸发冷却原理实验了一种新型新风换气机,即通过增大全热交换芯体处冷热气体的换热温差提高换热效率的换气机。 As a new type of ventilation equipment, the air converter is used to recover indoor air cooling(heat) in heat exchange core. To improve thermal efficiency, a new air converter with direct evaporative was developed, which improves thermal efficiency by increasing heat transfer temperature difference in heat exchange body.
作者 谢攀 宋泽琦 程阳 孙妍 马喆 金洪文 XIE Pan;SONG Ze-qi;CHENG Yang;SUN Yan;MA Zhe;JIN Hong-wen(College of Energy and Power Engineering,Changchun Institute of Technology;Jilin Province Building Energy Supply and Indoor Environment Control Engineering Research Centre)
出处 《建筑热能通风空调》 2019年第2期77-80,共4页 Building Energy & Environment
基金 国家级创新创业训练项目(201711927010)
关键词 新风换气机 湿膜 换热效率 new air ventilator wet film heat exchange efficiency
  • 相关文献

参考文献4

二级参考文献9

  • 1曹玉璋.传热学[M].北京:高等教育出版社,2000
  • 2GB/T21087-2007空气-空气能量回收装置[S].
  • 3GB/T18883-2002.室内空气质量标准[S].[S].国家质量监督检验检疫总局,卫生部,国家环境保护总局,2002.11..
  • 4GB50736.2012.民用建筑供暖通风与空气调节设计规范[S].中华人民共和国住房和城乡建设部,中华人民共和国国家质量监督检验检疫总局,2012.
  • 5GB 50189-2005.公共建筑节能设计标准[S],2005.
  • 6GB/T 50378-2014,绿色建筑评价标准[S].
  • 706K301,空气-空气能量回收装置选用与安装(新风换气机部分)[S].
  • 8龙惟定.试论我国暖通空调业的可持续发展[J].暖通空调,1999,29(3):25-30. 被引量:111
  • 9周孝清,陈沛霖.间接蒸发冷却器的设计计算方法[J].暖通空调,2000,30(1):39-42. 被引量:28