摘要
作者根据氢化物原位富集分析方法,研制了一台原子吸收用的石墨炉自动进样器。该仪器与原子吸收仪相配合,适于分析As,Se等能形成氢化物的诸元素。
A Model HG-100 automatic sampler is designed for the determination of hydrideforming dements by hydride generation-graphite furnace atomic absorption spectrometry with in situ concentration of hydrides on the Pd-Coated graphite tube. This technique gives 20~30 folds obtained by conventional HG-AAS or HG-AFS, and can be applied to determine hydride-forming dements at 10^(-11) level.
出处
《光谱学与光谱分析》
SCIE
EI
CAS
CSCD
北大核心
1992年第4期117-120,74,共5页
Spectroscopy and Spectral Analysis
关键词
氢化物
原位富集
石墨炉
进样器
Hydridc gcncration In situ concentration Graphite-furnace Sampler.