期刊文献+

消像散掠入射平场光栅谱仪及其在等离子体XUV光谱诊断中的应用 被引量:6

A stigmatic grazing incidence flat-field grating spectrograph and its application in XUV spectroscopic diagnastics of plasmas
原文传递
导出
摘要 研制成一台由柱面反射镜和球面反射镜组成的掠入射前置光学系统和变间距球面光栅组成的掠入射平场光栅谱仪,它不仅有较高的效率和光谱分辨,调整方便,而且还具有在4.4nm~30nm波长范围里同时获得一维空间分辨光谱的能力.用该谱仪成功地获得了线聚焦激光产生的Si,Cu及其它元素的等离子体柱的轴向空间分辨光谱.该谱仪很适合与具有平直接收表面的光电探测器,如软X射线条纹相机等联用以获得时间分辨光谱. A flat-field grating spectrograph with one demension spatial resolution was developed. The speotrograph, consisted of a grazing incidence collecting optics combined with a cylindrical mirror and a spherical mirror, and a variable line-spacing concave grating, has not only the advantages of easy adjustment, higher efficiency and higher spectral resolution, but also the capability to provide one demensional spatially resolved spectrum simutaneously over 4.4-30nm wavelength range. The spatially resolved on-axis spectra of Si, Cu and other element plasmas produced by line-focused laser were successfully obtained. Such a speotrograph is suitable for coupling with the deteotors having flat receiving surface, such as soft X-ray streak camera, to achieve the time-resolved XUV spectra.
出处 《光学学报》 EI CAS CSCD 北大核心 1992年第2期118-122,共5页 Acta Optica Sinica
基金 国家高技术计划 中国科学院重大项目的资助
关键词 光栅谱仪 空间分辨光谱 等离子体 stigmatio grazing incidence flat-field grating spectrograph spatially resolved spectra line-focused laser-plasmas.
  • 相关文献

参考文献2

  • 1范品忠,中国激光,1991年,18卷,1期,27页
  • 2张正泉,光学学报,1988年,8卷,8期,762页

同被引文献13

  • 1徐至展,中国科学.A,1991年,4期,414页
  • 2徐至展,Appl Phys B,1990年,50卷,4期,147页
  • 3徐至展,Appl Phys Lett,1990年,56卷,24期,2370页
  • 4徐至展,中国科学.A,1990年,1期,27页
  • 5Gong M,1992年
  • 6徐至展,光学学报,1991年,11卷,961页
  • 7毛楚生,核聚变与等离子体物理,1983年,3卷,2期,102页
  • 8倪云龙,强激光与粒子束,1991年,3卷,2期,242页
  • 9王世绩
  • 10李英骏,张杰,彭翰生,张启仁.可变入射距离平焦场谱仪的概念设计[J].强激光与粒子束,1998,10(3):409-413. 被引量:7

引证文献6

二级引证文献9

相关作者