摘要 采用厌氧-好氧生物法对薯干酒精糟液综合治理,结果表明:当设计进水COD<45000mg L,BOD<25000mg L,SS<25000mg L时,出水水质COD<300mg L,BOD<150mg L,SS<200mg L,出水达到了《污水综合排放标准》GB8978—1996规定的二级标准。该法在徐州房亭酒厂得到了实际应用。 The anaerobicaerobic biological technology is adopted to treat comprehensively the alcoholic waste liquor drainage from sweet potato. The result shows that the effluent will be COD<300 mg/L,BOD<150 mg/L,SS<200 mg/L,when the highly concentrated inflow with COD<45 000 mg/L,BOD<25 000 mg/L,SS<25 000 mg/L is given. The effluent is quite good to meet the national integrated wastewater discharge standard of Grade 2 specified by GB8978-1996. This method is put into practice in Xuzhou Fangting Brewery.
作者 赵传义
出处 《工业水处理》 CAS CSCD 2003年第2期62-64,共3页 Industrial Water Treatment
关键词 酒精糟液 厌氧发酵 好氧处理 brewery waste liquor anaerobic fementation aerobic treatment