期刊文献+

采用多泵并联变频调速技术实现机场恒压供油 被引量:6

Pressure-Control in the Airport Refueling System with Multi-Par allel Pumps,One of Which is Powered by a Frequency Converter
下载PDF
导出
摘要 深入研究了应用多泵并联变频调速技术实现民用机场恒压供油的原理 ,并通过分析给出了系统启泵、并泵、退泵和停泵的条件。所述的方案被成功地应用于多个民用机场的供油自动化系统 ,以其诸多优点成为现代化民用机场供油自动化系统的首选方案。 The principle of pressure control in the airport refueling system with multi p arallel pumps, one of which is powered by a frequency converter, is researched i n depth. The conditions of start pump, add pump, suctract pump and stop pum p are analyzed in the paper. The scheme given here is successfully used in seve ral airport refueling automation systems, and becomes the preferred scheme in th e modern airport refueling automation systems for its advantages.
出处 《航空学报》 EI CAS CSCD 北大核心 2003年第2期170-173,共4页 Acta Aeronautica et Astronautica Sinica
关键词 机场供油 自动化 变频调速 airport refueling automation frequency control