期刊文献+

直接荧光光度法测定水中痕量酚 被引量:1

Direct spectrofluorimetric determination of trace amounts of phenol in water
下载PDF
导出
摘要 建立一种新的荧光光度法分析水中痕量酚。水中的酚经紫外光照射后,激发强荧光(λex=273nm,λem=302nm)能直接进行荧光光度测定。检出限0.03μg·L^(-1),相对标准偏差0.29%,回收率97.5%~102.5%。方法简单、快速、精密度和准确度高、无毒、安全。 A new spectrofluorimetric determination of trace phenol in water was proposed in this paper. Phenol emit fluorescence under the irradiation of ultraviolet light. The excitation and emission wavelenths of phenol are 273nm and 302nm respectively. On this basis phenol can be detected directly by spectrofluorimetry. The detection limit is 0.03μg·L-1,the relative standard deviation is 0.29%(n=11) and the recovery is 97.5%-102.5%. The method is simple, rapid, precise and accurate.
作者 武玲
出处 《现代仪器》 2003年第2期35-35,38,共2页 Modern Instruments
关键词 直接荧光光度法 测定 Direct Spectrofluorimetry Trace phenol
  • 相关文献

参考文献3

  • 1GB 5750-85,15.1 4-氨基安替比林分光光度法测定挥发酚类
  • 2魏复胜.水和废水监测分析方法(第3版)[M].北京:中国环境科学出版社,1989.408.
  • 3王莜敏 徐伯兴 等.-[J].分析化学,1986,14(5):398-398.

共引文献2

同被引文献9

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部