期刊文献+

维生素B_2在电化学预处理玻碳电极上的电化学行为及其痕量测定 被引量:4

Electrochemical Behavior and Trace Determination of Vitamin B_2 at Electrochemically Pretreated Glassy Carbon Electrode
下载PDF
导出
摘要 用阳极氧化和循环扫描的方法电化学预处理得到的玻碳电极(PGCE)有一对可逆的氧化还原峰(Epa=- 0.0 73V,Epc =0.0 4 4V).PGCE能大大提高水溶性的维生素如维生素B2(VB2 )的电化学响应.实验表明VB2 在PGCE上是吸附行为.PGCE具有很强的稳定性,用其能测定痕量的VB2 和复合维生素片剂中的VB2 ,结果令人满意. An electrochemically pretreated glassy carbon electrode (PGCE) was achieved by anodic oxidation at 1.8?V and following potential cycling in the potential range from -0.8 to+1.0?V. The resulting PGCE gave well-defined redox peaks with E pa =-0.073?V, E pc =0.044?V. The PGCE showed good activity in improving the electrochemical responses of some water soluble Vitamin B 2 (VB 2), VB 2 could be adsorbed at PGCE. The PGCE was rather stable and can be used to trace determination of VB 2, and VB 2 in multivitamin vitamin tablets.
作者 顾海鹰
出处 《淮阴师范学院学报(自然科学版)》 CAS 2003年第1期37-41,共5页 Journal of Huaiyin Teachers College;Natural Science Edition
基金 国家自然科学基金资助项目(2 0 0 75 0 10)
关键词 维生素B2 玻碳电极(GCE) 电化学预处理玻碳电极(PGCE) vitamin B2 (VB2) glassy carbon electrode (GCE) electrochemically pretreated glassy carbon electrode (PGCE)
  • 相关文献

参考文献26

  • 1[1]Cabaniss G E, Diamantis A A, Rorer Murphy W, Jr, Linton R W, Meyer T J. El ectrocatalysis of proton-coupled electron-transfer reactions at glassy carbon electrode[J]. J Am Chem Soc, 1985, 107:1845-1853.
  • 2[2]Zhang H, Coury L A. Effects of high-intensity ultrasound on glassy c arbon electrodes[J]. Anal Chem, 1993, 65:1552-1558.
  • 3[3]Fagan D T, Hu I, Kuwana T. Vacuum heat treatment for activation of glassy carbon electrodes[J]. Anal Chem, 1985, 57: 2759-2763.
  • 4[4]Upadhyay P K. A simple procedure for activating a glassy carbon electrode [J]. J Electroanal Chem Interfacial Electrochem, 1989, 271(1-2): 339 -343.
  • 5[5]Bowling R J, Packard R T, McCreery R L. Activation of highly ordered pyro l ytic graphite for heterogeneous electron transfer: Relationship between electroc hemical performance and carbon microstructure[J]. J Am Chem Soc, 1989, 111:1 217-1223.
  • 6[6]McCreery R L. Carbon Electrodes: Structural Effects on Electron Transfer Kinetics. In Electroanalytical Chemistry(Bard A J Ed) [M]. New York:Marcel Dekker, 1991.
  • 7[7]Engstrom R C. Electrochemical pretreatment of glassy carbon electrodes [J]. Anal Chem, 1982, 54: 2310-2314.
  • 8[8]Engstrom R C, Strasser V A. Characterization of electrochemically pretrea tment glassy carbon electrodes[J]. Anal Chem, 1984, 56: 136-141.
  • 9[9]Bowers M L, Yenser B A. Electrochemical behavior of glassy carbon electro des modified by electrochemical oxidation[J]. Anal Chim Acta, 1991,243:4353.
  • 10[10]Millan K M, Spurmanis A J, Mikkelsen S R. Covalent immobilization of DNA onto glassy carbon electrodes[J]. Electroanalysis, 1992, 4:929-932.

二级参考文献1

  • 1Peng Wenfeng,J Electroanal Chem,1994年,375卷,198页

共引文献14

同被引文献49

引证文献4

二级引证文献11

相关作者