期刊文献+

轻柴油储罐火灾过程及安全性评价 被引量:8

Fire Process of Storage Tank for Light Diesel Oil and Its Safety Assessment
下载PDF
导出
摘要 从 2 0 0 2年 1月 1日起我国实施新的“轻柴油”产品标准 ,新标准将轻柴油的闪点指标由原来的≥ 65℃改为≥ 5 5℃ ,由此导致轻柴油的火灾危险类别发生变化 ,并进而引发原有轻柴油储罐能否安全储存新标准轻柴油的问题。笔者利用化学流体力学模型和挪威船级社 (DNV)的SAFETI风险评估软件对 65℃闪点和 5 5℃闪点轻柴油的储存火灾危害性进行了评估 。 A new product standard for light diesel oil had been enacted since January 1,2002 in China.In this standard,the flash point of light diesel oil was revised from≥65℃ to ≥55℃,so that its fire risk grade is altered.Whether the former storage tank can safely store the light diesel oil of new standard as before becomes a question.The model of chemical fluid mechanics and SAFETI of DNV are applied to evaluate the fire risk of light diesel oil of ≥55℃ and ≥65℃ respectively.The computerized simulated results for rire risk of light diesel oil are obtained.
出处 《中国安全科学学报》 CAS CSCD 2003年第2期54-59,49,共7页 China Safety Science Journal
关键词 轻柴油 闪点 火灾 储存 Light diesel oil Flash point Fire Storage
  • 相关文献

参考文献5

  • 1[1]V.I. Binov and G. N. Khadiakov. Certain Laws Governing Diffusive Burning of Liquids. SSSR Dokladv
  • 2[3]Johnson,A. D. A Model for Predicting Thermal Radiation Hazards from Large-scale Pool Fires. IChemE Symposium Series (1992) NO. 130:507~524
  • 3[4]Koseki, H. & Mulhlland, G.W. The Effect of Diameter on the Burning ofCrude Oil Pool Fires. Fire Technology, (1991)(2) :54~65.
  • 4[5]Yumoto, T. Burning Characteristics of 2.7 m Square Dike Fires. Report of Fire Research Institute of Japan, (1986) No. 61
  • 5[6]Johnson , B. P. A Comparison of Various Foams when used against Large Scale Petroleum Fires. Home Office, Fire Research and Development Group, Pub, 1993(2)