期刊文献+

炼制进口原油常减压装置的腐蚀问题 被引量:10

Corrosion of Atmospheric-vacuum Distillation Unit Processing Imported Crudes
下载PDF
导出
摘要 胜利炼油厂第三常减压装置改炼进口高硫原油或进口原油掺炼陆上原油后 ,设备腐蚀明显加重 ,致使换热器E2 4/ 1和空冷器A1/ 1腐蚀率高达 2 .5mm/a。腐蚀加重的主要原因是由于原油脱后盐含量偏高 ( 10~ 2 0mg/L)、硫含量高 ( 1.5 %~ 2 .5 % )所造成的塔顶及其冷凝冷却系统H2 S -HCl-H2 O环境的腐蚀 ,高温重油部位则主要是环烷酸引起的腐蚀。同时提出了改造电脱盐系统。 The corrosion began to deteriorate in the equipment of 3# atmospheric-vacuum distillation unit in Shengli Refinery when high-sulfur imported crudes or onshore crude blended with the imported crudes were processed. The corrosion rate of the heat exchanger E24/1 and air cooler A1/1 was as high as 2.5 mm/yr. The analysis indicated that the corrosion was mainly the H 2S-HCl-H 2O corrosion of the overhead and condensing system caused by higher salt content in the desalted crude (10~20 mg/L) and higher sulfur (1.5%~2.5%). The culprit of the corrosion in high-temperature heavy oil section was naphthenic acid. The protection measures such as revamping of the crude desalting system and optimization of the crude blending and chemical dosage were presented.
出处 《石油化工腐蚀与防护》 CAS 2003年第1期5-10,共6页 Corrosion & Protection In Petrochemical Industry
关键词 常减压装置 高硫原油 设备腐蚀 腐蚀监测 装置用材 防护措施 high-sulfur crude, media change, equipment corrosion, corrosion monitoring, material selection, protection measure
  • 相关文献

同被引文献76

引证文献10

二级引证文献27

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部