摘要 铅是一种污染性很高的物质,对人体、环境都有一定的危害作用,一直以来铅检测技术都受到科学界的关注。传统铅检测技术方式多样,但是检测技术成本高,流程复杂,在实际应用领域存在很大障碍,难以满足需求。生物化学检测技术因为其巨大优势,获得了越来越多的认可。本文对目前的几种生物化学中的铅检测技术进行了对比分析,综合比较其优劣势和发展前景,以此为新的铅检测技术的推广和深入研究提供一定的借鉴。 Lead is a highly polluting substance, which has a certain harm to the human body and the environment. The technology of lead inspection has been paid attention to by the scientific community for a long time. The traditional methods of lead inspection are various, but the detection technology has high cost and complicated process, so there are great obstacles in practical application and it is difficult to meet the demand. Biochemical detection technology has gained more and more recognition because of its great advantages. This paper makes a comparative analysis of several biological chemical lead detection technology in the present, comparing their advantages and disadvantages and development prospects, as the lead of new detection technologies and the promotion of further research to provide certain reference.
作者 段翰林
机构地区 吉林警察学院
出处 《科教导刊》 2017年第10X期48-49,共2页 The Guide Of Science & Education
关键词 铅检测 生物化学 研究分析 lead test biochemistry research and analysis
  • 相关文献

参考文献3

二级参考文献31

  • 1Blake R C,Delehanty J B, Khosraviani M,et al. Allosteric binding properties of a monoclonal antibody and its fab fragment[J]. Biochemistry, 2003,42 (2) : 497 - 508.
  • 2Khosraviani M, Blake I I, Pavlov AR, et al. Binding properties of a monoclonal antibody directed toward Lead-chelate complexes[J]. Bioconjugate Chemistry, 2000,11(2) : 267 - 277.
  • 3Blake D A,Jones R M,Blake R C. Antibody based sensors for heavy metal ions[J]. Biosensors and Bioelectronics,2001, 16(9 - 12) 799 - 809.
  • 4Delehanty J B,Jones RM, Bishop T C,et al. Identification of important residues in metal-chelate recognation by monoclonal an tibodies[J]. Biochemistry, 2003,42 (48) : 14173 - 14 183.
  • 5Zhu X X,Hu B S, Liu F Q, et al. Characterization of monoclonal antibodies for lead-chelate complexes: applications in antibodybased assays[J]. Journal of Agricultural and Food Chemistry, 2007,55 (13) : 4993 - 4998.
  • 6Adamczyk M, Fishpaugh J R, Heuser K J, et al. Synthesis of immunocomponents for the measurement of lead(Pb) by fluorescence polarization immunoassay[J]. Tetrahedron, 1998,54 (13) : 3092 - 3112.
  • 7Johnson D K,Combs S M,Parsen J D. Lead analysis by anti-chelate fluorescence polarization immunoassay[J]. Environmental Science & Technology, 2002,36 : 1042 - 1047.
  • 8Johnson D K. Fluorescence polarization immunoassays for metal ions[J].Combinatorial Chemistry and High Throughput Screening, 2003,6(3) :245 - 255.
  • 9Kim H K, Liu J, Li J, et al. Metal-dependent global folding and activity of the 8-17 DNAzyme studied by fluorescence resonance energy transfer[J]. Journal of the American Chemical Society,2007,129(21):6896- 6902.
  • 10Breaker R R,Joyce G F. A DNA enzyme that cleaves RNA[J].Chemistry and Biology, 1994,1 (4):223- 229.