摘要
通过对洛铜集团熔铸厂 2 #低频炉除尘系统改造过程中出现的问题及采取相应对策的总结 ,探讨了通过对风量和压头的分析来发现除尘系统问题所在的方法 ,具有较强的适用性 ,同时为反吹风袋式除尘器改造成脉冲袋式除尘器提供了范例。
In this paper,some corresponding methods adopted are analyzed and summarized,in accordance with the problems existed in the dust removal renovation of 2 # low frequency furnace in Cast Plant of Luoyang Copper Processing Group,which shows that it is applicable to find problems by analyzing the wind amount and pressure head and at the same time ahich provides an example for the counterwind bag filter changed into pulse bag filter.
出处
《工业安全与环保》
2003年第4期6-7,共2页
Industrial Safety and Environmental Protection