摘要
介绍了合肥国家同步辐射光源(HLS)新BPM校准系统的总体结构及实测过程。给出了待测真空管道的实测结果,并通过与国家同步辐射一期工程备份管测试结果的比较证实了本系统的精度较高。
A new BPM calibration system has been developed in the National Synchrotron Radiation Laboratory (NSRL). Eight sets of BPM which will be used in Phase-II Project of Hefei Light Source (HLS) have been calibrated with this system. The experimental results are also provided in this paper.
出处
《核技术》
CAS
CSCD
北大核心
2003年第4期254-256,共3页
Nuclear Techniques