期刊文献+

Effect of AXIS lateral mass screw-plate internal fixation system on functional recovery of spinal cord in fracture of lower cervical vertebrae 被引量:4

Effect of AXIS lateral mass screw-plate internal fixation system on functional recovery of spinal cord in fracture of lower cervical vertebrae
下载PDF
导出
摘要 AIM:To evaluate the methods and results of the AXIS lateral mass screw plate system in the treating of lower cervical spine injury.METHODS:29 cases of lower cervical vertebrae injury were fixed with AXIS system.All of them were followed up for more than 1 year.RESULTS:All cases had a good bone union without malformation.We found no complication of the injury to the vertebral arteries or nerves.There was no loosening of the plate and screw. CONCLUSION:AXIS lateral mass screw plate system has the characteristic of stable,simple and safe and is suitable for the treatment of lower cervical spine injury. AIM:To evaluate the methods and results of the AXIS lateral mass screw plate system in the treating of lower cervical spine injury.METHODS:29 cases of lower cervical vertebrae injury were fixed with AXIS system.All of them were followed up for more than 1 year.RESULTS:All cases had a good bone union without malformation.We found no complication of the injury to the vertebral arteries or nerves.There was no loosening of the plate and screw. CONCLUSION:AXIS lateral mass screw plate system has the characteristic of stable,simple and safe and is suitable for the treatment of lower cervical spine injury.
出处 《中国临床康复》 CSCD 2003年第6期998-999,T004,共3页 Chinese Journal of Clinical Rehabilitation
基金 SupportedbytheTackleKeyProblemsTopicofGuangdongProvince No.99B06703G
关键词 AXIS侧板钢板螺钉 内固定系统 下颈椎骨折脱位 颈髓功能恢复 internal fixators cervical vertebrae spinal cord fracture
  • 相关文献

同被引文献60

  • 1徐荣明,校佰平,冯建翔,龚遂良,张炳祥.颈椎椎弓根螺钉内固定技术有关问题探讨[J].脊柱外科杂志,2003,1(1):19-22. 被引量:18
  • 2徐荣明,马维虎,Ebraheim NA.颈椎侧块螺钉技术在下颈椎不稳定中的应用[J].脊柱外科杂志,2003,1(2):75-77. 被引量:13
  • 3Spivak JM, Chen D, Kummer FJ. The effect of locking fixation screws on the stability of anterior cervical plating. Spine 1999; 24:334 - 8
  • 4Ryken TC, Clausen JD, Traynelis VC, et al. Biomechanicai analysis of bone mieral density, insertion technique, screw torque, and holding strengh of anterior cervical plate screws. J Neurosurg 1995; 83:325 - 9
  • 5Coe JD, Warden KE, Stutterlin CE 3rd, et al. Biomechanical evaluation of cervical spinal stabilization mothods in human cadaveric model. Spine 1989; 14:1122 -31
  • 6Zdeblick TA, Cooke ME, Wilson D, et al. Anterior cervical discectomy, fusion,aand plating. Spine 1993; 18: 1794- 83
  • 7Connolly PJ, Esses SI, Kostuik JP. Anterior cervical fusion: Out-come analysis of patients used with and without anterior cervical plates. J Spinal Disord 1996; 9:202 - 6
  • 8Lowery GL, McDonough RF. The significance of hardware failure in anterior cervical plate fixetion. Spine 1998; 23:181 -6
  • 9Smith MD, Emery SE, Dudley A, et al. Vertebral antery injury daring anterior decompression of the cervical spine. A retrospective review of ten patients. J Bone Joint Surg Br 1993; 75:410 - 5
  • 10Ebraheim NA, Lu J, Brown JA, et al. Vulnerability of vertebral antery in anterolateral decompression for cervical spondylosis. Clin Orthop 1996; (322):146 -51

引证文献4

二级引证文献10

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部