期刊文献+

Flow-injection Chemiluminescence Sensor for the Determination of Gallic Acid by Immobilizing Luminol and Periodate on Anion-exchange Resin

Flow-injection Chemiluminescence Sensor for the Determination of Gallic Acid by Immobilizing Luminol and Periodate on Anion-exchange Resin
原文传递
导出
摘要 A novel chemiluminescence (CL) sensor for the determination of gallic acid combined with flow injection analysis was developed by electrostatically immobilizing luminol and periodate on anion-exchange resins respectively. Gallic acid was sensed by its enhancing effect on the weak CL reaction between luminol and periodate, which were eluted from the ion exchange column. The possible reaction mechanism of the CL system was suggested and discussed. The response of the sensor to gallic acid concentration was linear over the range of 8.0×10 -9-1.0×10 -6 mol/L with a detection limit of 6.5×10 -9 mol/L (3σ). The relative standard deviation (RSD) for 7 repetitive determinations of gallic acid (1.0×10 -7 mol/L) was 1.8%. The sensor could be used for over 400 times determination with a good reproducibility. A novel chemiluminescence (CL) sensor for the determination of gallic acid combined with flow injection analysis was developed by electrostatically immobilizing luminol and periodate on anion-exchange resins respectively. Gallic acid was sensed by its enhancing effect on the weak CL reaction between luminol and periodate, which were eluted from the ion exchange column. The possible reaction mechanism of the CL system was suggested and discussed. The response of the sensor to gallic acid concentration was linear over the range of 8.0×10 -9-1.0×10 -6 mol/L with a detection limit of 6.5×10 -9 mol/L (3σ). The relative standard deviation (RSD) for 7 repetitive determinations of gallic acid (1.0×10 -7 mol/L) was 1.8%. The sensor could be used for over 400 times determination with a good reproducibility.
出处 《Chinese Journal of Chemistry》 SCIE CAS CSCD 2002年第10期1049-1054,共6页 中国化学(英文版)
基金 ProjectsupportedbytheNationalNaturalScienceFoundationofChina (Nos .2 9975 0 13and 9835 110 )andtheDoctoralFoundationofEducationMinistryofChina (No.2 0 0 0 0 2 840 3)
关键词 chemiluminescence sensor gallic acid LUMINOL PERIODATE flow-injection analysis chemiluminescence sensor, gallic acid, luminol, periodate, flow-injection analysis
  • 相关文献

参考文献10

  • 1Qin W,Zhang Z J,Liu H J,Anal. Chemtracts . 1998
  • 2J Ueda,N Saito,Y Shimazu,T Ozawa.Comparison of scavenging abilities of antioxidants against hydroxyl radicals[].Archive of Biochemistry and Biophysics.1996
  • 3M Inoue,R Suzuki,T Koide,N Sakaguchi,Y Ogihara,Y Yabu.Antioxidant, gallic acid, induces apoptosis in HL60RG cells[].Biochemical and Biophysical Research Communications.1994
  • 4Richards S M E,Durham D G,Liu X.Antibacterizl activity ofcompounds from rubus punfaensis[].Planta Medica.1994
  • 5Inoue M,Suzuki R,Sakaguchi N,et al.Selective induction of cell death in cancer cells by gallic acid[].JBiol Pharm Bull.1995
  • 6Koch S,Ackermann G,Lindner P. Talanta . 1992
  • 7Kroes,B. H.Van Ven Berg, A.J. J. ; Quarles Van Ufford, H. C. ; Van Dijk, H. ; Labadie, R. P[].Planta Medica.1992
  • 8Dixon,J. S.,Lipkin,D.Spectrophotometric determination of vicinal glycols, application to the determination of ribofuranosides[].Analytical Biochemistry.1954
  • 9Bowen,E. J.Pure Appl[].Chemtracts.1964
  • 10Evmiridis,N. P. The Analyst . 1987