Simultaneous Laser Thermal Lens Spectrometric Determination of Trace Platinum and Palladium in an Aqueous Solution 被引量:1

Simultaneous Laser Thermal Lens Spectrometric Determination of Trace Platinum and Palladium in an Aqueous Solution
原文传递
导出
摘要 A selective and sensitive method for determination of platinum and palladium(II) in an aqueous solution simultaneously by laser thermal lens spectrometry, based on the complex reaction of 2-(3,5-dichloropyridylazo)-5-dimethylaminoamiline (3,5-diCl-PA^D~MA) with platinum and palladium, has been developed. It is shown that the palladium complex can be formed at room temperature, while the platinum complex can be only formed after being heated in a boiling water bath. By using this difference of reaction temperature and the characteristic of the complexes mentioned above, the method for simultaneous determination of platinum and palladium was established in an aqueous solution without a pre-separation. The results show that the dynamic linear ranges of determination for platinum and palladium are 0.005- 0.04 μg/mL and 0.005- 0.25 μg/mL respectively, and that the detection limits are both 0.002 μg/mL. The method has been applied to the determination of platinum and palladium simultaneously in alloy and catalyst samples with satisfactory results. A selective and sensitive method for determination of platinum and palladium(II) in an aqueous solution simultaneously by laser thermal lens spectrometry, based on the complex reaction of 2-(3,5-dichloropyridylazo)-5-dimethylaminoamiline (3,5-diCl-PA^D~MA) with platinum and palladium, has been developed. It is shown that the palladium complex can be formed at room temperature, while the platinum complex can be only formed after being heated in a boiling water bath. By using this difference of reaction temperature and the characteristic of the complexes mentioned above, the method for simultaneous determination of platinum and palladium was established in an aqueous solution without a pre-separation. The results show that the dynamic linear ranges of determination for platinum and palladium are 0.005- 0.04 μg/mL and 0.005- 0.25 μg/mL respectively, and that the detection limits are both 0.002 μg/mL. The method has been applied to the determination of platinum and palladium simultaneously in alloy and catalyst samples with satisfactory results.
出处 《Chinese Journal of Chemistry》 SCIE CAS CSCD 2002年第10期1055-1059,共5页 中国化学(英文版)
基金 ProjectsupportedbytheNaturalScienceFoundationofShaanxiProvinceofChina (No .97H0 1) .
关键词 laser thermal lens spectrometry simultaneous determination PLATINUM PALLADIUM 2-(3 5-dichloropyridylazo)-5-di-methylaminoamiline laser thermal lens spectrometry, simultaneous determination, platinum, palladium, 2-(3,5-dichloropyridylazo)-5-di-methylaminoamiline
  • 相关文献

参考文献10

  • 1Franko,M. Talanta . 2001
  • 2Barefoot R R,Van Loon J C. Talanta . 1999
  • 3Martin-Biosca,Y.Garcia-Alvarez-Coque, M.C. ; RamisRams, G[].TrAC Trends in Analytical Chemistry.1997
  • 4INES TORAL M,RICHTER P,LARA N,et al.iaminopyridine as chromophore ligand[].Analytical Letters.2000
  • 5Zhang X L,Zhang G.Simultaneous Spectrophotometric Determination of Trace Palladium and Rhodium with 2,4-TADAT[].Journal of Chemical Research.1994
  • 6Liu,G .Q,Zhang,G,Zhou,Y .M,Wang,G .F. AnalyticalLaboratoryofAnalysis . 1999
  • 7Fang,H .L,Swofford,R .L. UltrasensitiveLaserSpec troscopy . 1983
  • 8Yang,S .K,Yan,H .T. Chin.J.Anal.Sci . 1995
  • 9Morl,K,Imasaka,T,Ishibashi,N. Analytical Chemistry . 1982
  • 10Fujiwara,K,Lei,W,Uckiki,H,Shimokoshi,F,Fuwa,K,Kobayashi,T. Analytical Chemistry . 1982