摘要
分析认为《自动喷水灭火系统设计规范》(GBJ84 - 85 )和 (GB5 0 0 84 - 2 0 0 1)中系统设计流量算式存在着不够完善或比较繁琐 ,且难实际操作的问题。提出以 (GB5 0 0 84 - 2 0 0 1)第 9 1 4条规定的喷水强度为基点 ,计算出系统最大和最小设计流量 。
The calculation formula to determine the design discharge in the Design Norms of Automatic Sprinkling System (GBJ84-85) and (GB50084-2001) are inadequate and complicated, and not easy to use. It is thought that the calculation could be located on the basis of sprinkling intensity guided in clause 9 1 4 in the norm (GB50084-2001). In this way, we can calculate the maximum and minimum design discharges, and the design discharge might be finally determined by the number of nozzles installed in the practical acting area.
出处
《给水排水》
CSCD
北大核心
2003年第2期83-87,共5页
Water & Wastewater Engineering