摘要 利用一种温敏水凝胶作为毛细管电泳的填充介质 ,建立了毛细管电泳免疫分析血清中雌三醇的方法。研究了缓冲溶液的浓度和pH值、水凝胶的浓度、电压等因素对分析结果的影响。雌三醇的检出限和线性范围分别为 3 1 .6ng L和 5 0~ 5 0 0 0ng L。 A kind of thermally linear polymer-poly-N-isopropylacrylamide (PNIPA) was packed into capillary electrophoresis, which can be used to separate bound and free estroil antigen. A useful method for the determination of estroil in serum by capillary electrophoretic immunoassay was developed. The influence of concentration and pH of buffer, concentration of hydrogel, applied voltage etc. has been studied. The limit of detection and the linear range of estriol were 31.6 ng/L and 50 similar to 5000 ng/L, respectively.
出处 《分析化学》 SCIE EI CAS CSCD 北大核心 2003年第4期385-388,共4页 Chinese Journal of Analytical Chemistry
基金 国家自然科学基金 (No .2 0 0 75 0 0 1 2 0 0 75 0 0 3)资助项目
关键词 毛细管电泳免疫分析法 分析 雌三醇 温敏水凝胶 激光诱导荧光检测器 内源性激素 疾病 诊断 capillary electrophoresis immunoassay estriol laser-induced fluorescence detection hydrogel
  • 相关文献

参考文献13

  • 1[2]Kim S, Liva S M, Dalal M A, Veriry M A, Voskuhl R R. Neurology, 1999, 52(6):1230~1238
  • 2[3]Newby D, Aitken D A, Howatson A G, Connor J M. Placenta, 2000, 21(2/3): 263~267
  • 3[4]Benn P A, Collins R. Ann. Clin. Biochem., 2001, 38(1): 28~36
  • 4[5]Kos-Kudla B, Skalba P, Kudla M, Marek B, Ostrowska Z, Buntner B. Med. Sci. Monit., 1999, 5(2):285~288
  • 5[6]Tanaka T, Yanagi M, Kubodera A. Steroids, 1998, 63(10): 516~522
  • 6[7]Ito K, Oda M, Tsuji A, Maeda M. J. Pharm. Biomed. Anal., 1999, 20(1-2): 169~178
  • 7[8]Tagawa N, Tsuruta H, Fujinami A, Kobayashi Y. J. Chromatogr. B, 1999, 723(1+2): 39~45
  • 8[9]Xiao X Y, MaCalley D. Rapid Commun. Mass Spectrom., 2000, 14(21): 1991~2001
  • 9[10]Lagana A, Fago G, Marino A, Santarelli D. Anal. Lett., 2001, 34(6): 913~926
  • 10[11]Heikinheimo O, Ranta S, Grunberg S, Spitz I M. Steroids, 2000, 65: 831~836

同被引文献1058

引证文献10

二级引证文献57

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部