不同体位对双上肢CTA图像质量的影响 被引量:5

The Effect of Different Position on The Image Quality of Upper Extremity CT Angiography
原文传递
导出
摘要 目的探讨CT血管造影(CTA)在观察透析患者动静脉内瘘中的作用,以及成像过程中双上肢上举或自然下垂于腹部两种不同体位对图像质量的影响。方法回顾性分析20例上肢动静脉内瘘患者的CTA图像,10例在检查时双上肢上举,10例自然下垂置于腹部。在内瘘的动脉流入、动静脉吻合口、前臂和上臂静脉流出以及中心静脉分别设置感兴趣区(ROI),测量ROI的信噪比(SNR)和对比噪声比(CNR),评价图像质量。结果在流入动脉及动静脉瘘口处,不同体位下两组的SNR及CNR存在显著性差异。结论不同体位下两组图像均可用于临床诊断。如在患者可耐受范围内,推荐采用双上肢上举体位进行CTA检查,对流入动脉及动静脉瘘口显示更好。 Objective The purpose of our study was to discuss the utilization of CTA to evaluation hemodialysis arteriovenousfistulas(AVFs), and compare the effect of arm position on image quality. Methods Our study retrospectively analyzed the data of 20 patients with hemodialysis fistula who underwent MDCT angiography with arms raised above the shoulder region(n=10) or both arms were down(n=10).The regions of interests(ROIs) were set on distal arterial inflow, arteriovenous anastomosis, forearm, distal half of upper arm, proximal half of upper arm, and central veins. Subjective image quality was assessed with two parameters: signal-to-noise ratio and contrast to noise ratio. Results The arm raised group displayed better image quality on distal arterial inflow,arteriovenous anastomosis regions than both arms down group(P<0.05). Conclusion We recommended arms raised up as the first choice position when a patient with hemodialysis fistula underwent a upper extremity CTA examination.
作者 江桂莲 张婷婷 林思圆 张鹏 李静 JIANG Guilian;ZHANG Tingting;LIN Siyuan(Department of Radiology,Beijing Friendship Hospital of Capital Medical University,Beijing 100050,P.R.China)
出处 《临床放射学杂志》 CSCD 北大核心 2019年第3期558-562,共5页 Journal of Clinical Radiology
基金 国家自然科学基金项目(编号:61271151) 北京市自然科学基金项目(编号:7162048)
关键词 双上肢CT血管造影 动静脉內瘘 信噪比 对比噪声比 Upper extremity CT angiography Hemodialysis arteriovenous fistulas SNR CNR
  • 相关文献

参考文献4

二级参考文献44

  • 1李惠民,刘士远,于红,董生,叶朝阳.血液透析中血管通路的CT造影[J].中国医学计算机成像杂志,2005,11(5):350-354. 被引量:9
  • 2Barrett JF, Keat N. Artifacts in CT: recognition and avoidance. Radiographics, 2004, 24: 1679-1691.
  • 3Brink M, de Lange F, Oostveen LJ, et al. Arm raising at exposure controlled multi-detector trauma CT of thoracoabdominal region: higher image quality, lower radiation dose. Radiology, 2008, 249 : 661-670.
  • 4Sennst DA, Kachelriess M, Leidecker C, et al. An extensible software based platform for reconstruction and evaluation of CT images. RadioGraphics, 2004, 24: 601-613,.
  • 5Mastora I, Remy-Jardin M, Delannoy V, et al. Multi-detector row spiral CT angiography of the thoracic outlet: dose reduction with anatomically adapted online tube-current modulation and preset dose savings. Radiology, 2004, 230 : 116-124.
  • 6National Kidney Foundation. K/DOQI clinical practice guidelines for vascular access, update 2000. Am J Kidney Dis, 2001, 37(1): S137-S181.
  • 7Dumars MC, Thompson WE, Bluth El, et al. Management of suspected hemodialysis graft dysfunction: usefulness ofdiagnostic US. Radiology, 2002, 222(1): 103-107.
  • 8Chow LC, Rubin GD. CT angiography of the arterial system. Radiol Clin North Am, 2002, 40(4): 729-749.
  • 9Tsai IC, Lee T, Chen MC, et al. Homogeneous enhancement in pediatric thoracic CT aortography using a novel and reproducible method: contrast-covering time. Am J Roentgenol, 2007, 188(4): 1131-1137.
  • 10Neyman EG, Johnson PT, Fishman EK. Hemodialysis fistula occlusion: demonstration with 64-slice CT angiography. J Comput Assist Tomo, 2006, 30(1): 157-159.

共引文献22

同被引文献49

引证文献5

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部