摘要 由于蒸发式冷凝器冷凝盘管表面水流速度慢、水温高、蒸发率高等导致易结垢,且难于控制。本文通过实际工程改造采用电化学处理技术(ECT),去除水中的结垢因子并控制微生物繁殖和白锈腐蚀,并与化学处理法进行对比,发现电化学处理的循环水质各项指标明显优于化学法处理的水质。 Due to the slow water flow rate,high water temperature and high evaporation rate of the evaporating condenser condensing coil,it is easy to scale and difficult to control.In this paper,electrochemical treatment(ECT)is used to remove scale factors in water and control microbial growth and white rust corrosion.Compared with the chemical treatment method,it is found that the indexes of the circulating water quality of the electrochemical treatment are obviously superior to those of the chemical treatment.
作者 孙立宇 章明歅 罗先宇 邓建平 Sun Liyu;Zhang Mingyin;Luo Xianyu;Deng Jianping(Huashang International Engineering Co.,Ltd.,Beijing,100069;Aquagena Environment Technology(Beijing)Co.,Ltd.,Beijing,100101)
出处 《冷藏技术》 2019年第1期29-32,共4页 Journal of Refrigeration Technology
关键词 蒸发式冷凝器 循环冷却水 电化学水处理 evaporative condenser re-circulating system electrolysis cooling water treatment
  • 相关文献

参考文献2

二级参考文献6

  • 1John Lane EVAPCO,Inc. Taneytown, Maryland Non-Chemical Water Treatment for Evaporative Condensers.
  • 2王海山,等.给水排水常用数据手册.第二版.北京:中国建筑工业出版社,2001.
  • 3林选才,等.给水排水设计手册:第4册--工业给水处理.北京:中国建筑工业出版社,2002.
  • 4薛树森,等.工业循环冷却水处理设计规范,GB 50050-2007.北京:中国计划出版社,2008.
  • 5电力工程建设概算定额--建筑工程.北京:中国电力出版社,2001.
  • 6史一忠,戚邦胜.蒸发式冷凝器的选用与维护保养[J].冷藏技术,2002(4):31-34. 被引量:5