两种根管长度测量仪测量不同牙髓状态下根管工作长度准确性的比较 被引量:1

Comparison of the accuracy of two electronic apex locators measuring root canal working length in different pulp status
原文传递
导出
摘要 目的:比较两种根管长度测量仪测量不同牙髓状态下根管工作长度的准确性。方法:选取活髓牙和死髓牙各62个根管,随机分为4组,分别采用ProPex II和SybroEndo根管长度测量仪测量根管工作长度。WaveOne Gold机用镍钛器械预备根管至P号,25~#不锈钢K锉插入根管达工作长度,拍摄X线根尖片,通过PACS软件量取K锉尖端到牙根根尖的距离(D值)。统计分析各组测量准确率和D值差异。结果:SybroEndo根管长度测量仪组活髓和死髓状态下,准确率分别为93.56%和96.54%,均高于ProPex II组,分别为90.36%和92.54%,组间差异无统计学意义(P>0.05)。组间D值差异无统计学意义(P>0.05)。结论:ProPex II和SybroEndo根管长度测量仪在活髓牙和死髓牙的根管工作长度测定中均具有较高的准确率,值得在临床工作中选择应用。 Objective:To evaluate the accuracy of two electronic apex locators measuring root canal working length in different pulp status.Methods:Sixty-two root canals with vital pulp or necrotic pulp were randomly divided into four group.The working length were measured by ProPex II and SybroEndo electronic apex locators.All canals were prepared by WaveOne Gold NiTi rotary files to size P.And 25~#K files were inserted into the root canals to the working length and the X-ray was taken.The distance of the apical of 25~#K file to the root apical(D value)was measured by PACS software.The accuracy of each group and D value were statistically analyzed.Results:The accuracy of ProPex II vital pulp group and necrotic pulp group were 90.36%and 92.54%respectively.The accuracy of SybroEndo vital pulp group and necrotic pulp group were 93.56%and 96.54%respectively.There was no significant difference between each group(P>0.05).There was no significant difference of D value between each group(P>0.05).Conclusion:ProPex II and SybroEndo electronic apex locators both determined the working length with high accuracy and are recommended for clinical use.
作者 于飞 杨欣 袁敬 YU Fei;YANG Xin;YUAN Jing(Center of Stomatology,Tongji Hospital,Tongji Medical College,Huazhong University of Science and Technology,Hubei Wuhan 430030,China;Department of Integrated Medical Services,Tongji Hospital,Tongji Medical College,Huazhong University of Science and Technology,Hubei Wuhan 430030,China)
出处 《临床口腔医学杂志》 2019年第9期545-547,共3页 Journal of Clinical Stomatology
关键词 根管长度测量仪 根管工作长度 活髓牙 Electronic apex locators Root canal working length Vital pulp
  • 相关文献

参考文献3

二级参考文献21

  • 1范兵,边专,樊明文.牙体牙髓临床治疗Ⅱ. 根管预备的工作长度、宽度和锥度[J].中华口腔医学杂志,2006,41(3):184-187. 被引量:27
  • 2黄力子.根管长度电测法及其原理[J].中华口腔医学杂志,1988,23(5):297-297.
  • 3Lauper R. J Endod,1996,22(5):260~263
  • 4Kobayashi C, Suda H. J Endod,1994,20(3):111~114
  • 5Vajrabhaya L, Tepmorgkol P. Endod Dent Traumatol, 1997, 13(4): 180~182
  • 6Kaufman AY, Fuss Z, Keila S, et al. Int Endod J, 1997,30(6):403~407
  • 7Fouad AF,Krell KV,Mckendry DJ,et al. J Endod, 1990,16(9):446~449
  • 8Frank Al, Torabinejad M.J Endod, 1993,19(4): 177~179
  • 9Pagavino G, Pace R, Baccetti T. J Endod, 1998,24(6):438~441
  • 10Shabahang S. J Endod,1996,22(11):616~618

共引文献22

同被引文献9

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部