摘要
针对自动发电控制 (AGC)的现状 ,浅述AGC运行过程与大机组闭环控制 ,尤其是与汽温控制的关系。结合扬州第二发电有限责任公司的实际应用 ,分析AGC与锅炉超温的内在联系和不同工况下的影响。
In view of the status quo concerning automatic generation control (AGC), the relationship between operation process of AGC and closed loop control, especially the steam temperature control of large-scale units, has been elementarily stated. Combined with the practical application in Yangzhou Power Generation Company Ltd No.2, the internal relations between AGC and overtemperature of boilers, as well as the influence under different operating conditions has been analysed.
出处
《热力发电》
CAS
北大核心
2003年第3期5-7,32,共4页
Thermal Power Generation