摘要 高纯五氧化二钒样品在硝酸-氢氟酸(4+1)混合液中经微波消解处理,采用电感耦合等离子体质谱法测定样品溶液中15种杂质元素(钛、硅、铝、铬、镍、铜、铅、砷、磷、铁、锰、钙、镁、钾、钠)的含量。采用内标法消除基体的影响。方法的检出限(3s/k)在0.03~0.89μg·L-1之间。方法的加标回收率在90.0%~113%之间,相对标准偏差(n=8)小于5.0%。五氧化二钒5号样品中8种杂质元素的测定值与石墨炉原子吸收光谱法进行核对,测得结果互相符合。 The sample of vanadium pentoxide was treated with a mixture of HNO3and HF(4+1)by microwave assisted digestion,and contents of 15impurity elements(i.e.Ti,Si,Al,Cr,Ni,Cu,Pb,As,P,Fe,Mn,Ca,Mg,K and Na)in the sample solution were determined by ICP-MS.The matrix interference was eliminated by internal standard method.Detection limits(3s/k)of the method found were in the range of 0.03-0.89μg·L-1.Tests for recovery were made by standard addition method,giving values of recovery in the range of90.0%-113%and RSD′s(n=8)found were less than 5.0%.Contents of 8impurity elements in sample 5#were checked by GF-AAS method,consistent values were obtained.
作者 成勇
出处 《理化检验(化学分册)》 CAS CSCD 北大核心 2014年第6期745-748,共4页 Physical Testing and Chemical Analysis(Part B:Chemical Analysis)
关键词 电感耦合等离子体质谱法 微波消解 五氧化二钒 杂质元素 ICP-MS Microwave assisted sample digestion Vanadium pentoxide Impurity elements
  • 相关文献

参考文献2

二级参考文献14

  • 1胡净宇,王海舟.ICP-MS测定铜锌合金中痕量元素[J].冶金分析,2004,24(6):1-5. 被引量:26
  • 2GUSTAVSSON Ingemar,GRANFORS Michael.飞行时间-电感耦合等离子体质谱法测定钢、镍基合金及锆锡合金中痕量元素(英文)[J].冶金分析,2007,27(2):8-12. 被引量:16
  • 3THOMPSON M,WALSH J N.ICP光谱分析指南[M].北京:冶金工业出版社,1991.
  • 4钢铁及铁合金化学分析方法标准汇编(上)[M].北京:中国标准出版社,1997:12.
  • 5WINGE R K,FASSEL V A,PETERSON V J,et al.电感耦合等离子体发射光谱图册[M].北京:中国光学学会光谱学会翻译汇编,1986.
  • 6Mcleod C W,Date A R,Cheung Y Y.Metal oxide ions in inductively coupled plasma-mass spectrometric analysis of nickel-base alloys[J].Spectrochimica Acta Part B:Atomic Spectroscopy,1986,41B(2):169-174.
  • 7Tan S H,Horlick G.Matrix effect observations in inductively coupled plasma mass spectrometry[J].J.Anal.Atom.Spectrom.1987,2(8):745-763.
  • 8Coedo A G,Dorado M T,Padilla I.Evaluation of a desolvating microconcentric nebulizer in inductively coupled plasma mass spectrometry to improve the determination of arsenic in steels[J].Appl.Spectrosc.1999,53(8):974-978
  • 9Coedo A G,Dorado M T,Padilla I.Evalution of different sample introduction approaches for the determination in unalloyed steels by inductively coupled plasma mass spectrometry[J].Spectrochimica Acta Part B:Atomic Spectroscopy,2005,60(1):73.
  • 10Hui-tao Liu,Shiuh-Jen Jiang.Dynamic reaction cell inductively coupled plasma mass spectrometry for determination of silicon in steel[J].Spectrochimica Acta Part B:Atomic Spectroscopy,2003,58 (1):153-157.

共引文献34

同被引文献42

引证文献5

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部