摘要 通过对GB/T 228.1-2010中的应变控制、频率带宽、采样频率、柔度等进行探讨,对三思纵横制造的试验机进行了产品技术定位。得出了应变控制有段时间很难达到应变速率误差在±20%之内,采样频率并不总是越快越好以及试验机质量的提高需要相关行业的支持等结论。 Through discussing on the strain control,frequency bandwidth,sampling frequency and compliance in GB/T 228.1-2010,product technology positioning was done to the tensile testing machine manufactured by SUNS.Conclusions such as it is difficult to control the strain rate within±20%error range during aperiod of time when using strain control,the sampling frequency is not always the sooner the better,and better quality testing machine needs the support of related industries were obtained.
出处 《理化检验(物理分册)》 CAS 2014年第2期101-105,共5页 Physical Testing and Chemical Analysis(Part A:Physical Testing)
关键词 万能试验机 柔度 采样频率 应变速率 universal testing machine compliance sampling frequency strain rate
  • 相关文献

参考文献3

二级参考文献10

  • 1GB/T228.1-2010金属材料拉伸试验第1部分:室温试验方法[s].
  • 2GB/T228-2002.金属材料室温拉伸试验方法[S].[S].,..
  • 3GB228-76,金属拉力试验法[S].
  • 4ASTM A370--2012 Standard test methods and defi nitions for mechanical testing of steel products[S].
  • 5高怡斐,梁新帮,邓星临.GB/T228.1-2010《金属材料拉伸试验第1部分:室温试验方法》实施指南[M].北京:中国质检出版社/中国标准出版社,2012.
  • 6GB/T228.1-2010金属材料拉伸试验第1部分:室温拉伸试验方法[S].
  • 7ISO 6892:2009 Metallic materials--Tensile testing at ambient temperature[S].
  • 8涂应宏.ISO/FDIS6892-1:2008中方法A推出的背景和意义[J].冶金分析,2010(增刊:物理分册):1255-1259.
  • 9AEGERTER J, BLOCHING H, SONNE H M. Influ ence of the testing speed on the yield/proof strength [J]. Materials Testing, 2001,10: 393-403.
  • 10李和平.拉伸、冲击、硬度试验方法国际标准的改进和问题[J].工程与试验,2010,50(B12):72-76. 被引量:6