摘要 P110钢级油管应用于某井的试油作业过程中,短时间内发生了大量的接箍纵向开裂失效。通过宏微观分析、化学成分分析、力学性能试验、金相检验以及腐蚀产物分析等方法分析了该接箍开裂的原因。结果表明:开裂起源于接箍外表面,系油管材料在井筒内硝酸盐介质作用下于承受周向拉应力最大的接箍外表面处发生应力腐蚀开裂。 Large quantities of cracking happened to P110 grade tubing couplings fractured inside within a short time after being applied in a well for oil test operation.The cracking reasons were analyzed by means of macro and micro analysis,chemical compositions analysis,mechanical properties test,metallographic examination and corrosion products analysis.The results show that the cracking initiated from the exterior surface of the coupling where the axial tensile stress was the largest,and under the action of nitrate inside the well casing stress corrosion cracking happened.
出处 《理化检验(物理分册)》 CAS 2015年第4期293-296,共4页 Physical Testing and Chemical Analysis(Part A:Physical Testing)
关键词 P110油管 接箍 应力腐蚀开裂 硝酸盐 P110 tubing coupling stress corrosion cracking(SCC) nitrate
  • 相关文献

参考文献3

  • 1陈学东.湿H2S及硝酸盐环境中低合金高强度钢制压力容器应力腐蚀开裂敏感性条件分析与安全保障技术研究[D].浙江大学2004
  • 2胡世炎编著.机械失效分析手册[M]. 四川科学技术出版社, 1999
  • 3Specification for casing and tubing. API Spec 5CT .