摘要
对引进ABB -CE公司燃烧器摆动技术初期燃烧器喷嘴热态摆动产生的问题进行了分析 ,采取了相关改进措施 ,并成功地应用到 1 995年以后设计的配直吹式制粉系统的 1 0 2 5t/h和 2 0 0 8t/h锅炉上 ,取得了良好的效果。
This paper analyzes the problem of the hot status tilting of burner nozzle,which is originally used the transferred burner tilting technology from ABB CE .The relative advanced measures are taken and successfully applied to the design of direct fired pulverized coal system of 1025 t/h and 2008 t/h boiler since 1995 and achieve the expected result.
出处
《锅炉技术》
北大核心
2003年第2期29-33,共5页
Boiler Technology
关键词
燃烧器喷嘴摆动
可靠性
措施
the tilting of burner nozzle
reliability
measures