摘要 对GB/T  85 3 8— 1995 水氟离子选择电极测定法 (简称“水标法”)以及WS/T  89— 1996 尿氟离子选择电极测定法 (简称“尿标法”)与山西省地方病研究所曾沿用的一种水尿氟离子选择电极同时测定法 (简称“旧法”)进行比较 。 In this paper, made a comparison between determination of fluoride ion in water selective electrode analysis GB/T 8538-1995 (called water standard method in the paper), determination of fluoride ion in urine selective electrode analysis WS/T 89-1996 (called urine standard method in the paper), and determination of fluoride ion in water and urine at the same time selective electrode analysis that was used in Shanxi Prevention and Cure Endemic Disease Institute (called old method in the paper), which explained equivalent character between old method and two other methods.
出处 《太原科技》 2003年第2期48-49,共2页 Taiyuan Science and Technology
关键词 水尿氟 测定 缓冲液 离子选择电极法 水标法 尿标法 污染水 尿液 氟病 water standard method, urine standard method, old method, equivalent character
  • 相关文献

参考文献3

  • 1张淑兰,傅玉治.掩蔽剂对水氟测量精度的影响[J].地方病通报,1996,11(2):56-58. 被引量:1
  • 2.GB/T 8538—1995饮用天然矿泉水检验方法[M].北京:中国标准出版社,1996.83.
  • 3.WS/T 89-1996 尿中氟化物的测定,离子选择电极法[M].北京:中国标准出版社,1997..