期刊文献+

氢化物发生—原子荧光光谱法测定饮用水中锡 被引量:2

Determining Tin in Drinking Water with Hydride Generation-Atomicfluorescence Spctrometry
下载PDF
导出
摘要 应用氢化物发生—原子荧光光谱法测定饮用水中锡,此法准确度、精密度令人满意。实验选定最佳工作条件:载气400mL/min,屏蔽气800mL/min,灯电流60mA,负高压-320V。方法检出限为0.34μg/L,线性范围为(0~40.0)μg/L。目前测定饮用水中的锡国家还没有制定标准检验方法,本文的工作可为饮用水中锡的标准检验方法的制定做些探索。 Hydride generation-atomic fluorescence spectrometry is used to analyze tin in drinking water. Experiment is done in best work condition;carry gas 400mL/min,closed gas 800mL/min,furnace high 8mm,bulb electric current 60mA, negative high voltage-320V, The determination limit of tin is 0. 34uμg/L,the linear rangeis (0-40. 0)μg/L. The method is simple and sensitive. It is satisfactory in precise and meticulous. There are no standard methods of nation determining tin in drinking water. Our work is to explore the method of determining tin in drinking water.
作者 尚鑫 张艳
出处 《锦州师范学院学报(自然科学版)》 2003年第1期17-19,共3页 Journal of Jinzhou Normal College (Natural Science Edition)
关键词 饮用水 水质检验 含量测定 氢化物发生-原子荧光光谱法 hydride generation atomic fluorescence spectrometry
  • 相关文献

参考文献4

二级参考文献12

共引文献60

同被引文献40

  • 1李飞.原子荧光光谱法测定水中低含量锡[J].环境监测管理与技术,2005,17(4):28-28. 被引量:8
  • 2刘莺.原子荧光光度法同时测定水中砷、硒的不确定度分析[J].中国环境监测,2007,23(3):14-17. 被引量:2
  • 3P. G. Georgopoulos, A. Roy, M. J. Yonone Lioy, J. Toxicol. Environ[J]. Health, Part B, 2001, 4:341 - 394.
  • 4Thorfinnur Gunnlaugsson, Joseph P. Leonard, Niamh S. Murray. Highly Selective Colorimetric Naked - Eye Cu (II) Detection Using an Azobenzene Chemosensor[J]. Org. Lett. , 2004, 6 (10) : 1557-1560.
  • 5Ruilong Sheng, Peng fei Wang, Yun hua Gao, et al. Colofimetric Test Kit for Cu^2+ Detection[J]. Org. Lett. ,2008, 10 (21) : 5015 -5018.
  • 6Xu Zhaochao, Xiao Yi, Qian Xuhong, et al. Ratiometric and Selective Fluorescent Sensor for Cu (II) Based on Internal Charge Transfer (ICT)[J]. Org. Lett., 2005, 7 (5) : 889 - 892.
  • 7Xu Zhaochao, Qian Xuhong, Cui Jingnan. Colorimctric and Rafiomctric Fluorescent Chcmoscnsor with a large Red - Shift in Emission: Cu (II) - Only Sensing by Dcprotonation of Secondary Amines as Receptor Conjugated to Naphthalimide Fluorophore[J]. Org. Lett. , 2005 , 7 (14) : 3029 - 3032.
  • 8Marta Beltramello, Maddalena Gatos, Fabrizio Mancin, et al. A new selective fluorecscence chemosensor for Cu (II) in water [ J ]. Tetrahedron Lett. , 2001, 42 : 9143 - 9146.
  • 9Valeria Amendola, Luigi Fabbrizzi, Carlo Mangano, et al. Signal Amplification by a Fluorescent Indicator of a pH - Driven Intramolecular Translocation of a Copper ( II ) Ion[J]. Angew. Chem. , 2002, 114 (14) : 2665 - 2668.
  • 10Yuri Diaz Fernandez, Aurora Perez Gramatges, Valeria Amendola, et al. Using micelles for a new approach to fluorescent sensors for metal cations[J]. Ghem. Commun. , 2004,14: 1650 - 1651.