期刊文献+

微波在线消解流动注射光度分析方法测定环境废水中总磷 被引量:5

On line microwave digestion for the determination of total phosphorus in waste water samples by flow injection spectrophotometry
下载PDF
导出
摘要 报道了微波在线消解流动注射光度分析方法测定环境废水中总磷。研究了消解管路的长度和内径,消解剂的种类和微波功率等实验参数的影响。每小时可分析20~25个水样,方法的测定精度为RSD=1 5%(n=10),废水样品中总磷的测定结果与德国标准分析方法一致。 A on-line microwave digestion flow injection system is described for the determination of total phosphorus in waste water samples with spectrophotometric detection in this paperThe optimization of experimental parameters such as length and diameter of digestion tube,reagent concentration,and microwave power were discussedCalibration has been found to be linear to 10 mg/L phosphorusWaste water samples can be analyzed at a rate of 20-25 samples per hour with a typical RSD of 15%(n=10)The determination results for total phosphorus in waste water samples agree with those obtained by standard digestion method from a German industrial standard(DIN)
出处 《冶金分析》 CAS CSCD 北大核心 2003年第2期1-4,共4页 Metallurgical Analysis
关键词 流动注射光度分析 微波在线消解 环境废水 测定 总磷 phosphate on-line microwave digestion flow injection
  • 相关文献

参考文献9

  • 1Aoyagi M,Yasumasa Y,Nishida A.Anal.Chim.Acta[J],1988,214:229.
  • 2Hirai Y,Yoca N,Ohashi S.Anal.Chim.Acta[J],1980,115:269.
  • 3Hirai Y,Yoza N,Ohashi s.Chem.Lett.[J],1980,5:499.
  • 4Gluodenis Jr T J,Tyson J F.J.A.A.S.[J],1992,7:301.
  • 5Carbonell V,Guardia M de la,Salvador A,et a1.Anal.Chim.Acta[J],1990,238:417.
  • 6Haswell S J,Barclay D.Analyst[J],1992,117:117.
  • 7Welz B,Tsalev D L,Sperling M.Anal.Chim.Acta[J],1992,261:91.
  • 8Woo L,Maher W.Anal.Chim.Acta[J],1995,315:123.
  • 9Hinkamp S,Schwedt G.Anal.Claim.Acta[J],1990,236:345.

同被引文献100