摘要
理论计算和堆上试验表明,5MW 低功率堆(LPR)具有较好的固有安全性。在失去外电源事故停堆工况下,靠本身自然循环和大水池的储热能力,不依靠任何其它安全设施就可导出堆芯余热,保证反应堆的安全。
It is proved by theory analysis and some tests relative to in-herent safety that the 5MW LPR has favourable inherent safety.When Loss-of-pump power accident take place and the reactorscramed simultaneously,the reactor can be ensured,and thedecay heat is removed out of the reactor core only by naturalcirculation.
出处
《核动力工程》
EI
CAS
CSCD
北大核心
1992年第4期81-86,共6页
Nuclear Power Engineering
关键词
低功率
固有安全性
反应堆
安全性
5MW Low Power Reactor
Natural circulation
Inherent safety
Flow inversion