摘要
本文简要地介绍了我国第一座脉冲堆稳态运行试验方法和设施,给出了冷态和热态以及不同功率下的临界棒位,并给出了反应性、中子通量、功率系数、平衡氙毒和碘坑的测量结果,提供了一批有价值的工程试验数据。本堆实现了1MW 稳态功率运行,进行了连续72小时满功率运行,对反应堆的控制、保护、测量仪器及各系统和设备进行了考验。试运行结果表明:本堆性能良好,各项指标均已达到了设计要求。
The paper briefly introduces the operational tests methodsand facilities at steady state of the first pulsed reactor of Chi-na.The critical positions of the control rods in cold and hot re-actor core and various power condition are given The reactivi-ty,neutron flux,power coefficient,equilibrium Xenon poisoningand Iodic pit are measured and the results are shown.A numberof valuable engineering test data are provided.The pulsed reactor has realized 1MW steady-state operation,it has gone a steady-state trail run at full power for 72 hours.Reactor control and protection systems,instrumentation,andvarious systems and equipments were tested.The reactor showsgood performances in compliance with the design specification.
出处
《核动力工程》
EI
CAS
CSCD
北大核心
1992年第5期37-43,共7页
Nuclear Power Engineering
关键词
脉冲堆
运行
中子通量
试验
Pulsed reactor
Steady-state operation
Reactivity
Neutron flux
Power test