摘要
5MW低功率堆(5MW LPR)自动棒逻辑系统采用了多重联锁与手动在役检查,提高了逻辑系统的可靠性和安全性。文中介绍了逻辑系统的设计特点及功能。
The safety and reliability of the logical syatem for 5MW LPRautomatic rod are improved,because of using multi-interlock andmanual check on line.The design character and function of thelogical system are introduced in this paper.
出处
《核动力工程》
EI
CAS
CSCD
北大核心
1992年第6期67-70,共4页
Nuclear Power Engineering
关键词
联锁
在线
检查
反应堆
逻辑系统
5MW Low Power Reactor
Multi-interlock
Manual check on line