摘要
武汉国际会展中心空调系统冷热源为蓄冷、蓄热方式 ,蓄冰系统采用主机位于上游的串联形式 ,蓄热设备为自然分层的垂直层流型蓄热槽。大空间展厅采用喷口送风分层空调。工程已投入运行 。
Selects ice storage and heat storage as cold and heat sources of the air conditioning system in Wuhan International Exhibition Centre. In the ice storage system the chiller is located upstream in series form, and the thermal storage system involves a vertical laminar flow heat storage tank of natural stratification. Applies nozzle outlet in large exhibition space. The project operated meets the design demand.
出处
《暖通空调》
北大核心
2003年第2期82-84,共3页
Heating Ventilating & Air Conditioning