期刊文献+

用一或二份血样本^(131)I-OIH血浆清除法测定肾有效血浆流量 被引量:1

Measurement of effective renal plasma flow by plasma clearance of ~131I -Hippuran using one or two blood sampling
下载PDF
导出
摘要 研究了29例病人注射^(131)I—OIH后10—90min内获取6份血浆标本作清除曲线,用双室模型分析计算出ERPF作为参考标准。单份49min样本代替完整清除曲线所得结果的标准估计误差(Sy-x)为65.6ml/min,而两样本法(10和90min)的Sy·x可减小到20.7ml/min。 Twenty nine patients were studied by obtaining six plasma samples for each clearance curve at 10 to 90 min after injection as a reference standard. ERPF has been calculated from a two-compartment model analysis (Sapirtein Method). The standard error of estimate (Sy.x) by single 49 min sample was 65.6ml/min. By using two samples (at 10 and 90 min), Sy.x-could be reduced to 20. 7ml/min.
出处 《核技术》 CAS CSCD 北大核心 1992年第11期692-695,共4页 Nuclear Techniques
关键词 ERPF 肾功能试验 碘131 Effective renal plasma flow 131I - Hippuran
  • 相关文献

参考文献1

  • 1W. Newlon Tauxe,Eva V. Dubovsky,Travis Kidd,Fernando Diaz,L. Richard Smith. New formulas for the calculation of effective renal plasma flow[J] 1982,European Journal of Nuclear Medicine(2):51~54

同被引文献1

  • 1钱桐荪,肾脏病学(第2版),1990年

引证文献1

二级引证文献31

相关作者