期刊文献+

Study of Temperature Distribution Along an Artificially Polluted Insulator String 被引量:24

Study of Temperature Distribution Along an Artificially Polluted Insulator String
下载PDF
导出
摘要 Insulator becomes wet partially or completely, and the pollution layer on itbecomes conductive, when collecting pollutants for an extended period during dew, light rain, mist,fog or snow melting. Heavy rain is a complicated factor that it may wash away the pollution layerwithout initiating other stages of breakdown or it may bridge the gaps between sheds to promoteflashover. The insulator with a conducting pollution layer being energized, can cause a surfaceleakage current to flow (also temperature-rise). As the surface conductivity is non-uniform, theconducting pollution layer becomes broken by dry bands (at spots of high current density),interrupting the flow of leakage current. Voltage across insulator gets concentrated across drybands, and causes high electric stress and breakdown (dry band arcing). If the resistance of theinsulator surface is sufficiently low, the dry band arcs can be propagated to bridge the terminalscausing flashover. The present paper concerns the evaluation of the temperature distribution alongthe surface of an energized artificially polluted insulator string. Insulator becomes wet partially or completely, and the pollution layer on itbecomes conductive, when collecting pollutants for an extended period during dew, light rain, mist,fog or snow melting. Heavy rain is a complicated factor that it may wash away the pollution layerwithout initiating other stages of breakdown or it may bridge the gaps between sheds to promoteflashover. The insulator with a conducting pollution layer being energized, can cause a surfaceleakage current to flow (also temperature-rise). As the surface conductivity is non-uniform, theconducting pollution layer becomes broken by dry bands (at spots of high current density),interrupting the flow of leakage current. Voltage across insulator gets concentrated across drybands, and causes high electric stress and breakdown (dry band arcing). If the resistance of theinsulator surface is sufficiently low, the dry band arcs can be propagated to bridge the terminalscausing flashover. The present paper concerns the evaluation of the temperature distribution alongthe surface of an energized artificially polluted insulator string.
出处 《Plasma Science and Technology》 SCIE EI CAS CSCD 2003年第2期1715-1720,共6页 等离子体科学和技术(英文版)
关键词 temperature distribution artificially polluted insulator string temperature distribution artificially polluted insulator string
  • 相关文献

参考文献8

  • 1Vitelli M, et al. Temperature distribution along an outdoor Insulator subjected to different pollution levels. IEEE Trans. on Dielectrics and Electrical Insulation, 2000, 7(3): 416 ~ 423
  • 2Mizuno Y, et al. Voltage and temperature distribution along semi conducting glaze insulator strings. IEEE Trans Dielectrics and Electric Insulation, 1999, 6(1): 100 ~ 104
  • 3Gorur Ravi S, Edward Cherney, Jeffrey Burnham.text book on "Outdoor Insulators", Phoenix, Arizona, USA 1999
  • 4IEC - 507-1991-04, Artificial Pollution tests on high voltage Insulators to be used on ac systems.1991
  • 5Subba Reddy B, Nagabhushana G R. A portable .layer conductivity meter. paper accepted for Publication in Journal of Instrument society of India
  • 6IEC Report Publication -815-1986, Guide for the selection of insulators in respect of polluted conditions. 1986
  • 7CIGRE Task force 33-04-01, Polluted Insulators:A review of current knowledge, 1999
  • 8Subba Reddy B, Nagabhushana G R. A basic approach to phenomena of pollution induced flashovers. paper accepted for presentation at 13th International symposium on High Voltage Engg, to be held in August 2003, at TU-Delft,Netherlands