期刊文献+

流体诱发热电偶套管振动损坏分析 被引量:1

Analysis on the Damage by Fluid-induced Vibration of the Thermocouple Tube
下载PDF
导出
摘要 本文简单介绍了流体诱发旋涡脱落导致工程结构振动的机理,分析了用于测量流体温度的热电偶套管断裂的原因,并提出了防止热电偶套管振动断裂的预防措施。 In this paper, the mechamism of flow-induced vortex shedding that results in engineering structure vibration is briefly introduced, so, the causes of breakage of the thermocouple tube are analysed and measures of preventing breakage due to vibration of the thermocouple tube are proposed.
作者 张冶
出处 《河北电力技术》 1992年第1期51-55,共5页 Hebei Electric Power
  • 相关文献

参考文献1

共引文献8

同被引文献6

  • 1刘小兵,曾永忠.混流式水轮机中旋涡流的LES法预测[J].大电机技术,2006(1):41-48. 被引量:3
  • 2白莱文斯RD 吴恕三 译.流体诱发振动[M].北京:机械工业出版社,1983.45-50.
  • 3张阿漫,戴绍仕.流固耦合动力学[M].北京:国防工业出版社.2011.
  • 4Aoi H, Zhao Y, Hayase T. Improvement of the damaged thermowell of the monju fast-breeder reactor based on vibration analysis[J]. Simulation, 2002, 78(8) : 504 -511.
  • 5Haslinger K H. Flow-induced vibration testing of replacement thermowell designs [ J ]. Journal of Fluids and Structures, 2003, 18 ( 3 - 4) : 425 - 440.
  • 6于洪波,李霞.热电偶套管断裂的原因分析及预防措施[J].石油化工自动化,2008,44(2):86-87. 被引量:19