邯峰发电厂 2× 6 6 0MW汽轮发电机组的汽机本体采用湿式喷涂的施工方法进行保温 ,增加了保温的整体性、均匀性、严密性和装饰性 ,其保温结构还使机组的检修更加方便。通过对已投入运行的 1号汽轮机本体进行温度测试 ,证明喷涂保温效果良好 。
The thermal insulation of steam turbine proper of 2×660 MW units in Hanfeng Power Plant was carried out with the wet spray coating technology,which enhances the integrity, uniformity, tightness and nice-looking of the thermal insulation, and its structure provides with more convenience for maintenance.Through the surface temperature measurement of steam turbine proper of Unit No.l in service, a good thermal insulation result is confirmed with all parameters meeting the operation requirements.