摘要 旧城区改造房屋的独立基础设计,往往受到场地限制,较为经济可行的方法是设计成单向偏心基础。偏心基础由于有偏心荷载作用,可能会引起基础倾斜或转动。因此,设计时可考虑基础与刚性联接柱协同工作。本文根据文献等资料进行分析,得出较为实用、安全、可靠的设计方法。 The independent foundation design in the reconstruction of former city proper is apt to be restricted by the area, therefore it is a rational economy consideration to design on the basis of unidirectional eccentric foundation. Since the foundation slope or move is arisen from the eccentric foundation for its eccentric load, so it may be considered to give the coordination between foundation and rigid connecting pillar upon design. Based on the document, this article analyses and proposes a practical,safe and reliable design draft.
作者 李健俊
出处 《冶金丛刊》 2003年第2期8-12,共5页 Metallurgical Collections
关键词 独立偏心基础 偏心距 基底最大压力 基础转动 协同工作 independently eccentric foundation maximum foundation pressure foundation move coordinate operation
  • 相关文献

参考文献3

  • 1杨位洗.地基及基础(第三版)[M].中国建筑工业出版社,1998..
  • 2[美]JE·波勒斯编 唐念慈等译.基础工程分析与设计[M].中国建筑工业出版社,1987..
  • 3.GBJ7—89.《建筑地基基础设计规范》[S].,..