期刊文献+

旋转横向流膜器环隙压力测试系统的研究 被引量:2

STUDY ON PRESSURE MEASUREMENT SYSTEM FOR THE ANNULAR GAP OF MEMBRANE SEPARATOR WITH ROTARY CROSS-FLOW
下载PDF
导出
摘要 利用Delphi及Access 2000作为软件开发工具,研制了高精度的计算机控制的在线膜器环隙压力测试系统。可准确、方便、可靠地进行旋转横向流膜器环隙内的压力测试和渗透通量计算,亦可用于一般横向流与轴向流膜器的压力及通量测试。对膜微滤过滤机理的进一步研究,提供了有效的手段。 An on-line pressure measuring system for annular gap of membrane separator is developed, with the aid of computer. This system has high precision by using advanced software developing tools, such as Delphi and Access 2000. It can detect the annular gap pressure and the permeating flux in the rotary crass-flow membrane separator fairly accurately and reliably, also can be applied to the measurement of pressure and flux for other kinds of membrane separators, and provides the effective means for further research on enhancement mechanism in membrane micro-filtration.
出处 《机械工程学报》 EI CAS CSCD 北大核心 2003年第4期116-119,共4页 Journal of Mechanical Engineering
基金 国家自然科学基金资助项目(29976025)
关键词 膜分离 压力测量 旋转横向流膜器 环隙 渗透通量 Membrane separating On-line Pressure measurement
  • 相关文献

参考文献2

  • 1王成端.旋转切向流强化管式膜微滤的机理研究:[博士学位论文].成都:四川大学,2001.
  • 2Fisher E,Raasch J.Cross-flow filtration.Ger.Chem.Eng.,1985,(8):211~217.

同被引文献43

  • 1刘建力,王龙兴,戴海平,王静娟.微滤膜技术在茶饮料澄清中的应用[J].食品与发酵工业,2004,30(2):97-99. 被引量:11
  • 2吴俊奇,滕华,于莉.旋转流膜生物反应器膜透水特性研究[J].给水排水,2004,30(7):19-22. 被引量:4
  • 3董秉直,陈艳,高乃云,邓慧萍,范瑾初.混凝对膜污染的防止作用[J].环境科学,2005,26(1):90-93. 被引量:65
  • 4毕海丹,崔旭海,张永忠.膜技术在乳品工业中应用的最新进展[J].食品与发酵工业,2005,31(3):99-104. 被引量:10
  • 5彭文博,漆虹,陈纲领,邹琳玲,邢卫红,徐南平.19通道多孔陶瓷膜渗透过程的CFD模拟[J].化工学报,2007,58(8):2021-2026. 被引量:30
  • 6Voges L E,Benjamin M M,Chang Y,Use of iron oxides to enhance metal removal in crossflow microfiltration [ J ]. Journal of Environmental Engineering, 2001,127 (5): 411 ~ 419
  • 7Ma H, Nidsen D R, Bowman C N, et al, Membrane surface modification and backpulsing for wastewater treatment [ J ]. Separation Science and Technology, 2001,36 ( 7 ): 1557 ~1573
  • 8Wakeman R J. Electrically enhanced microfiltration of albu min suspensions [ J ]. Food and Bioproducts Processing: Transactions of the Institution of Chemical Engineers (Part C), 1998,76(3) :53~59
  • 9Czekaj Piotr, Mores Wendy,Davis Robert H, et al. Infrasonic pulsing for foulant removal in crossflow microfiltration [J]. Journal of Membrane Science, 2000, 180 ( 12 ): 157 ~169
  • 10Scott K, Mahmood A J ,Jachuck R J, et al, Intensified membrane filtration with corrugated membranes[J], Journal of Membrane Seience,2000, 173( 1 ): 1 ~ 16