摘要
对三相感应调压器的短路状态作了简要分析,对主要参量电压、电流、阻抗等进行了定量分析,并绘制了曲线与相量图,提出了对该种调压器进行温升试验的方法。
The short circuit problem of the three -phase induction -voltage regulator is analyzed briefly.The main parameters such as voltage,current and impedance are quantitatively analyzed.The curve and rectorgram are drawn.The temperature rise test method for the requlator is given.
出处
《变压器》
北大核心
2003年第5期17-19,共3页
Transformer