摘要 介绍了新余发电有限责任公司发电机内冷水系统采用TTA +EA处理的应用工艺 ,其处理效果优于采用BTA The applied technology for tolytriazole as copper inhibitar in the Water internally cooled type of generator in Xinyu power plant is introduced. The experiments show that the treatment effect of TTA+EA is better than that of BTA+EA.
出处 《江西电力》 2003年第2期30-31,35,共3页 Jiangxi Electric Power
关键词 发电机 内冷水系统 TTA 铜缓蚀剂 防腐处理 QFSN-200-2型 thermal power plant water internally cooled type of generators tolytriazole copper inhibitor TTA