期刊文献+

Interaction analysis between induction motor loads and STATCOM in weak grid using induction machine model 被引量:2

Interaction analysis between induction motor loads and STATCOM in weak grid using induction machine model
原文传递
导出
摘要 Static synchronous compensators(STATCOM)can be used as a reactive power compensation for induction motor(IM)loads due to its effective control and good compensation.Terminal voltage control(TVC)in a STATCOM has a great influence on voltage dynamics which is a significant concern in a system with many IM loads.This paper investigates the interaction between IM loads and TVC in a STATCOM under weak grid conditions from the viewpoint of active and reactive power flow.A corresponding induction machine model is proposed,based on which the interaction mechanism between IM loads and TVC in a STATCOM can be intuitively understood.It is shown that the negative damping component provided by TVC in a STATCOM can lead to system oscillation instability.Grid strength and the inertia constant of the induction machine affect the extent of such interaction.Time-domain simulation results of IM loads connected to an infinite system through a long transmission line,with STATCOM compensation implemented in MATLAB/Simulink,validate the correctness of the analyses. Static synchronous compensators(STATCOM)can be used as a reactive power compensation for induction motor(IM)loads due to its effective control and good compensation.Terminal voltage control(TVC)in a STATCOM has a great influence on voltage dynamics which is a significant concern in a system with many IM loads.This paper investigates the interaction between IM loads and TVC in a STATCOM under weak grid conditions from the viewpoint of active and reactive power flow.A corresponding induction machine model is proposed,based on which the interaction mechanism between IM loads and TVC in a STATCOM can be intuitively understood.It is shown that the negative damping component provided by TVC in a STATCOM can lead to system oscillation instability.Grid strength and the inertia constant of the induction machine affect the extent of such interaction.Time-domain simulation results of IM loads connected to an infinite system through a long transmission line,with STATCOM compensation implemented in MATLAB/Simulink,validate the correctness of the analyses.
出处 《Journal of Modern Power Systems and Clean Energy》 SCIE EI 2018年第1期158-167,共10页 现代电力系统与清洁能源学报(英文)
基金 supported in part by National Basic Research Program of China (973 Program) (No.2012CB215100) Major Program of National Natural Science Foundation of China (No.51190104) National Natural Science Fund for Excellent Young Scholars (No.51322704)
关键词 INDUCTION machine Small signal stability Static SYNCHRONOUS compensator(STATCOM) Terminal voltage control WEAK GRID Induction machine Small signal stability Static synchronous compensator(STATCOM) Terminal voltage control Weak grid
  • 相关文献

参考文献1

二级参考文献8

共引文献230

同被引文献5

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部