期刊文献+

泵系统管线局部凸起水锤防护措施的研究 被引量:32

Water hammer protection for pipe with local salience in pump system
下载PDF
导出
摘要 针对舒安泵站供水系统的特点 ,应用水锤基本理论和特征线方法 ,对系统无任何防护措施和加设水锤防护措施的事故停泵水力过渡过程进行了计算机数值模拟 ,对空气阀和单向调压塔两种防管道负压措施进行了比较分析 .计算结果表明 ,在局部凸起点附近加装单向调压塔更能较好地避免液柱分离的发生 . In accordance with the characteristic of water supply system at Shu′an Pump Station, computer simulation was made in the transition process of accidental pump-stop with protection measures and without measures by the basic theories of water hammer and the method of characteristic line. The air-valve was compared with one-way tank, both of which are used for avoiding liquid column separation in the pipe. The calculating results showed that one-way tank was effective and important to improve reliability of pump system and its stability.
出处 《华中科技大学学报(自然科学版)》 EI CAS CSCD 北大核心 2003年第5期65-67,共3页 Journal of Huazhong University of Science and Technology(Natural Science Edition)
关键词 泵站 液柱分离 水锤防护 pump station liquid column separation water hammer protection
  • 相关文献

参考文献4

  • 1蒋劲,李继珊,翁晓红,符向前.小浪底电站技术供水回水系统水锤防护研究[J].华中科技大学学报(自然科学版),2002,30(4):81-83. 被引量:11
  • 2刘竹溪 刘光临.泵站水锤防护[M].北京:水利水电出版社,1998..
  • 3怀利 E B 斯特里特V L 清华大学流体传动与控制教研组译.瞬变流[M].北京:水利电力出版社,1987..
  • 4怀利EB 斯特里特VL 清华大学流体传动与控制教研组译.瞬变流[M].北京:水利电力出版社,1987..