期刊文献+

3种活动代型定位器定位精度的比较 被引量:1

Positional accuracy of three removable die systems
下载PDF
导出
摘要 目的 对新研制的产品Pri-trac定位器的定位性能进行检测,并与钉、盘2种定位器的定位性能进行比较。方法 用Pri-trac、Accu-trac和Tecno-line pin定位器制作活动代型,测量锯开前和锯开后反复取戴30次的三维位置改变,测量精度为1μm。结果 3种定位器制作的活动代型,在水平面上的位置改变无显著性差异,在垂直方向上Tecno-line pin定位器制作的活动代型明显向上移位。结论 Pri-trac定位器的定位精度已达Accu-trac定位器的定位标准,在垂直方向上两种盘式定位器较Tecno-line pin定位器精确。 Objective This study evaluates the positional accuracy of a new product-Pri-trac system,and compared the positional accuracy between the pin system and tray system. Method Removable dies were made with Pri-trac, Accu-trac and Tecno-line positional systems and the three dimenttional positional changes between preremoval and postremoved die postilion were measured with 1 μm of measurement accuracy. Results Three systems are not significantly different on horizontal plane, although the Tecno-line pin has a significant movement in the vertical plane.Conclusion The positional accuracy of Pri-trac system has achieved the standard of Accu-trac system while the two tray systems are more accurate than Tecno-line Pin system in vertical direction.
作者 黄艳 王贻宁
出处 《口腔材料器械杂志》 2003年第2期77-79,共3页 Chinese Journal of Dental Materials and Devices
关键词 活动代型定位器 定位精度 比较 Pri-trac定位器 Accu-trac定位器 Tecno-line pin定位器 Removable die system Removable die Positional accuracy
  • 相关文献

参考文献9

  • 1黄艳.活动代型定位器在口腔修复中的应用[J].国外医学(口腔医学分册),1999,26(4):218-221. 被引量:2
  • 2左运农 黄钊 覃发军.增强金瓷冠边缘适合性的制作体会[J].口腔医学纵横杂志,1996,12:116-117.
  • 3Stephen F, Rosenstiel MF. Contemporary Fixed Prosthodontics Edl.The C.V. Mosby Company. 1988,361-382.
  • 4Frank JM, Walter ED. Comparative stability of two removable die systems. J Prosthet Dent. 1976,36:326-333.
  • 5Myers M, Hembree JH. Relative accuracy of four removable die systems. J Prosthet Dent. 1820,48:163-165.
  • 6Covo LM, Zievert GJ, Baothazar Y, et al. Accuracy and comparative stability of three removable die systems. J Prosthet Dent. 1988,59:314-317.
  • 7Richardson DW, Sanchez RA, et al. Positional accuracy of four die tray systems. J Prosthet Dent. 1991,63:39.-45.
  • 8Netli CA, Yard RA., WIthrow G. Saw modification for underside die cutting. J Prosthet Dent. 1990,64:621-623.
  • 9Araameuni P, Millstein P. A comparision of the accuracy of two removable die systems. Int J Prosthet. 1993,6:533-539.

二级参考文献4

  • 1周志忍.公共组织绩效评估—英国的实践及对我们的启示[J].新视野,1995,(5).
  • 2[美]戴维·H·罗森布鲁姆 罗伯特·S·克拉夫丘克.公共行政学:管理、政治和法律的途径[M].中国人民大学出版社,2002.476.
  • 3[美]史蒂文·科恩 威廉·埃米克.新有效公共管理者[M].北京:中国人民大学出版社,2001.160.
  • 4周晓玮.我国公务员绩效测评的困境与原因初探[J].理论探讨,2003(3):22-23. 被引量:36

共引文献2

同被引文献6

  • 1左运农 黄钊 覃发军.增强金瓷冠边缘适合性的制作体会[J].口腔医学纵横杂志,1996,12:116-117.
  • 2[1]Robert AT.Die trimming:A guide to physiologic contour. J Prosthet Dent,1982,42:485~489.
  • 3[3]Sorensen JA.A standaridized method for determination of crown margin fidelity. J Prosthet Dent, 1990,64:18~20.
  • 4[7]George WK, David AJ. Factors effecting seating and fit of complete crowns :A computer simulation study. J Prosthet Dent,1985,53:276~278.
  • 5[8]Holmes JR,Stephen CB.Consideration in measurement of marginal fit .J Prosthet Dent, 1989,62:406~408.
  • 6万红,杜传诗,吴德全.粘固剂对烤瓷熔附金属底层冠就位的影响[J].华西口腔医学杂志,1991,9(4):256-259. 被引量:17

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;