期刊文献+

湍球塔脱硫的冷态试验研究 被引量:12

Cold test and study of flue gas desulfurization on turbulent contact absorber
下载PDF
导出
摘要 在自行设计的湍球塔上进行烟气脱硫的冷态试验,研究不同工况下风量、静止床层高度、喷淋量、pH值和二氧化硫进口的质量浓度等主要影响因素与脱硫效率间的关系。试验结果表明,在适当的工况下脱硫效率可达89.9%,为工业化规模设计、操作和运行提供了所必需的基础数据。 The cold test of flue gas desulfurization(FGD)on turbulent contact absorber(TCA)in different conditions were conducted.The relations between the main affecting parameters(quantity of wind,height of still stuffing,spraying quantity of alkali liquor,pH value of absorbent solution and inlet SO 2 concentration)and SO 2 removal efficiency were studied.The test results indicated that,the desulfurization efficiency in proper conditions could achieve89.9%.These tests and study provided the necessary basic data for the design,handling and operation of industrized scale FGD facilities.
出处 《中国电力》 CSCD 北大核心 2003年第2期57-59,共3页 Electric Power
基金 中国博士后科学基金资助项目(2001年度) 辽宁省自然科学基金资助项目(01101014) 沈阳市科学技术计划项目(SK0105)
关键词 烟气脱硫 湍球塔 冷态试验 二氧化硫 大气污染 脱硫效率 coal-fired boiler FGD turbulent contact absorber(TCA) cold test
  • 相关文献

参考文献1

  • 1化学工业部设备设计技术中心站.塔设备设计[M].上海:上海科学技术出版社,1988.421.

共引文献1

同被引文献74

引证文献12

二级引证文献41

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部