摘要
从工艺角度对氨合成塔内件泄漏的原因和位置进行了分析和判断 ,并提出内件泄漏的预防措施。
Based on the present technology used, the causes of leakage and its position in inside part of ammonia synthesis tower were analyzed and determined. The preventive measures for leakage were put forward.
出处
《煤化工》
CAS
2003年第2期35-37,共3页
Coal Chemical Industry
关键词
氨合成塔
内件
泄漏原因
预防措施
ammonia synthesis tower, inside part, leakage, catalyst