摘要
通过对蒸气直接加热加湿的催芽间高温高湿环境的原理分析和讨论,提供了一种适用于高温高湿环境的比较简单的空调方式和有关计算方法,其室内相对湿度接近饱和状态,而室内温度不低于空调房间的室外温度。
Here the author analyses the design theory that adopts a way of steam dirict heating and damping,anduses the theory to design high temperature and high humidity in budding room .Then the author puts forward a relativesimple air-condition means and a calculate method that can be used under the following conditions: a high temperatureenvironment whose indoor relative humidity approaches saturated state ,and indoor temperature no less than air condi-tioning room outdoor temperature.
出处
《制冷空调与电力机械》
2003年第2期36-38,54,共4页
Refrigeration Air Conditioning & Electric Power Machinery
关键词
催芽间
高温高湿环境
蒸气
空调
计算方法
室内空气
bud-develop room
environment with high temperature and high humidity
steam
air-condition
calculate method.