期刊文献+

氧分子在镍钛合金(100)表面吸附行为的研究 被引量:4

The study of Oxygen adsorption behavior on NiTi (100) surface
原文传递
导出
摘要 NiTi形状记忆合金作为一种广泛使用的生物医学材料,表面形成的氧化膜是其具有良好生物相容性的基础。氧分子在NiTi合金表面的吸附是其形成氧化膜的关键,应用离散变分X_α方法,首次对O_2分子在B_2结构NiTi(100)表面的吸附过程进行了理论研究,分别计算了在两种不同的O_2分子吸附方式中Ti-O原子间的键级和电荷分布。结果表明:O_2分子垂直接近NiTi(100)表面对其发生吸附更为有利。在吸附过程中,O_2分子中只有一个氧原子被其最近邻的一个表面钛原子所吸附,而合金中其它表面原子及体相原子的电子结构没有变化。Mulliken集居数及局域态密度分析表明,吸附过程中钛原子与氧原子之间的相互作用主要是由2p(O)电子和4s,4p(Ti)电子贡献。 NiTi shape memory alloy is widely used as a biomaterial for the good compatibilities of its surface titanium oxide. Oxygen adsorption on NiTi surface is important for the formation of titanium oxide, the discrete variational Xa method(DV- Xa ) within the framework of density-functional theory is applied to study O2 molecule adsorption process on NiTi(100) surface. The bond order and charge distribution between Ti atom and O atom for two possible O3 molecule adsorption ways on NiTi (100) surface is calculated it is found that the adsorption way for O - O bond perpendicular to NiTi( 100) surface more preferred than that for O - O bond parallel to NiTi( 100) surface. O2 molecule only interacts with the nearest surface titanium atom from it during the adsorption process. The electronic structure of the other surface atoms and bulk atoms are not altered. Mulliken population and partial density of state analysis show that the interaction between Ti atom and O atom is mainly donated by the 2p (O) electrons and the 4s, 4p(Ti) electrons during the adsorption process.
出处 《计算机与应用化学》 CAS CSCD 北大核心 2003年第3期323-326,共4页 Computers and Applied Chemistry
关键词 氧分子 镍钛合金 表面吸附行为 形状记忆合金 生物医学材料 离散变分Xa方法 NiTi shape memory alloy surface adsorption the discrete variational Xa method
  • 相关文献

参考文献9

  • 1Andreasen G. A clinical trial of alignment of teeth using O. 019 - inch thermalnitinol wire with tranaitienal temperature range between 31℃ and 45. Am J Orthod, 1980, 78: 528 - 37.
  • 2Simon M, Athanasoulis C A, Kim D, et al. Simon nitinol inferior vena eava filter: initial clinical experience: work in progress. Radiology,1989, 172: 99- 103.
  • 3Pocek M, Maspes F, Masala S, et al. Palliative trestment of neoplastic strictures by self-expanding NiTi Strecker stent. Eur Radiol, 1996, 6:230-5.
  • 4Blum U, Voshage G, Lammer J, et al. Endoluminal stent-grafts for infrarenal abdominal aortic aneurysms. N Engl J Med, 1997, 336:13 -20.
  • 5Wever D J, Veldhuizen A G, Vries J, Busscher H J, et al. Electrochemical and surface characterization of a nickel-titanium alloy. Biomsterials, 1998, 19:761-9.
  • 6Christine T, Maryam Tabrizian, L' Hocine Yahia, Luc Bilodeau, Dominigue L Piron. Effect of modification of oxide layer on NiTi stent corrosion resistance. J Biomed Mater Res, 1998, 43:433 -440.
  • 7Ryhaenen J, Niemi E, Serlo W, et al. Biocompatibility of nickel-titanium shape memory metal and its corrosion behavioar in human cell cultures. J Biomed Mater Res, 1997, 35:451-7.
  • 8Meng C G, Guo JT, Hu Z Q. J relationship between bonding characteristics and mechanical properties of I42 intermetallics. Alloys and Compounds, 1996, 237: 139.
  • 9Zhao C C, Meng C C, Hua Y J. Relationship betwwen bonding festures and brittleness of intermetallics. Material Science and Engineering,1999, 17: 50.

同被引文献40

  • 1徐昕,吕鑫,王南钦,张乾二.金属氧化物表面化学吸附和反应的量子化学簇模型方法研究(英文)[J].物理化学学报,2004,20(F08):1045-1054. 被引量:2
  • 2倪哲明,吴念慈,郑小明.甲醇在催化剂MgO(100)面上吸附的量子化学研究[J].分子催化,1995,9(2):132-138. 被引量:5
  • 3来蔚鹏,薛永强,赵红.纳米金刚石反应热的量子化学研究[J].计算机与应用化学,2005,22(9):703-706. 被引量:6
  • 4华英杰,王崇太,孟长功.NiTi合金表面镍离子释放的电子结构理论计算[J].计算机与应用化学,2005,22(12):1115-1118. 被引量:6
  • 5曹锡章.无机化学[M].武汉:武汉大学出版社,1994.151-159.
  • 6Castelman LS and Motzkin SM.Biocompatibility of clinical implants materials.ed,D F Williams (CRC Press,Boca Raton,1981) 1:129-154.
  • 7Wever DJ and Veldhuizen AG,et al.Electrochemical and surface characterization of anickel-titanium alloy.Biomaterials,1998:761-769.
  • 8Trigwell S,Hayden RD and Nelson KF,et al.Effects of surface treatment on the surface chemistry of NiTi alloy for biomedical applications.Surface and Interface Analysis,1998,26 (7):483-489.
  • 9Daniel J,Chwirut H,Semih Oktay and Tara Ryan.Nitinol interventional cardiology devices-FDA's perspective.Proceedings of the Second International Conference on Shape Memory and Superelastic Technologies,USA,California,1997:377-379.
  • 10Wang XX,Mao ZY,Cao ZW and Qing RY,et al.The oxide film and its effect on shape memory effect and biocompatibility in a TiNi alloy.Proceedings of the International Symposium on Shape Memory materials,Beijing China,1994:621-625.

引证文献4

二级引证文献28

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部