期刊文献+

天津基岩热储对井系统回灌与示踪剂试验研究 被引量:10

STUDY ON TRACER TEST AND REINJECTION OF DOUBLET SYSTEM IN TIANJIN BASEROCK RESERVOIR
下载PDF
导出
摘要 地热回灌效应 ,与热储构造关系密切。在WR4 5对井系统抽水试验中发现在回灌井和开采井之间不存在明显的水力联系 ,地质条件分析也显示在这两眼井之间热储层连通性较差。为了探明回灌井和生产井之间连通渠道 ,1998年至 1999年冬季在WR4 5进行示踪剂试验。结果表明生产井中可监测示踪剂浓度主要与热储层的地质和水文条件有关。 The system with a long priod was analyzed.The temperature changer have not been observed in surrounding production well up to now.The well test and geological analyses indicated that a poor connection between the production well and reinjection well of the WR45 system.A tracer test was carried out for investigating the connect passage of the WR45 system in the winter of 1998 1999.The test showed that monitored concentration of tracer in the production well was mainly related with hydro geology framework.The tracer test was very important for understanding the transport way and transport channel/space in doublet production/reinjection system,and estimating the possible cooling resulting from the injection.
作者 王坤 朱家玲
出处 《太阳能学报》 EI CAS CSCD 北大核心 2003年第2期162-166,共5页 Acta Energiae Solaris Sinica
关键词 对井系统 回灌 示踪剂 doublet system reinjection tracer test
  • 相关文献

参考文献3

  • 1卢润 等.[R].,1985.1—10.
  • 2王坤.[R].,2001.17—19.
  • 3Axelsson G 等.冰岛低温热田回灌试验[A]..Proceedings of the World Geothermal Congress 1995[C].Florence,Italy,1995.1991-1996.

同被引文献207

引证文献10

二级引证文献140

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部