分析了6种供热空调系统方案在3种不同运行情况下的一次能源利用率PER,得出燃气热泵的PER最高.但在供热空调系统可行方案的优选中,方案的选择受多种因素影响,其中许多不能量化的指标常被忽略,决策时产生偏差.利用多目标决策的方法,对多目标系统进行优选,从环境因素、成本因素和性能因素等方面对6种采暖空调系统方案进行综合评价研究,给出了方案选择的指导性意见,提高了方案决策的合理性和科学性.
This paper analyzes primary energy ratio(PER)of six different heating and airconditioning systems under three different conditions and concludes that PER of the gas engine heat pump is highest.The optimum selection of feasible heating and airconditioning systems is not to be influenced only by a single factor,but by several factors,many of which can not be calculated and are ignored sometimes.That will lead to a deviation in making a decision.Based on the multiple objective decision and evaluation method,this paper evaluates six heating and airconditioning systems in regard to environmental impact,cost and performance and so on,then gives some suggestions on application.This method can conduce to making scientific decisions for projects.